Thermally stable graft-type polymer electrolyte membranes consisting based on poly (ether ether ketone) and crosslinked graft-polymers for fuel cell applications

https://repo.qst.go.jp/records/78214
https://repo.qst.go.jp/records/78214
ab8b247c-c39a-4063-9af7-3ef96c6e0d05
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-12-23
タイトル
タイトル Thermally stable graft-type polymer electrolyte membranes consisting based on poly (ether ether ketone) and crosslinked graft-polymers for fuel cell applications
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hasegawa, Shin

× Hasegawa, Shin

WEKO 999469

Hasegawa, Shin

Search repository
Hiroki, Akihiro

× Hiroki, Akihiro

WEKO 999470

Hiroki, Akihiro

Search repository
Maekawa, Yasunari

× Maekawa, Yasunari

WEKO 999471

Maekawa, Yasunari

Search repository
Ohta, Yuko

× Ohta, Yuko

WEKO 999472

Ohta, Yuko

Search repository
Iimura, Nobuaki

× Iimura, Nobuaki

WEKO 999473

Iimura, Nobuaki

Search repository
Fukaya, Atsuko

× Fukaya, Atsuko

WEKO 999474

Fukaya, Atsuko

Search repository
Shin, Hasegawa

× Shin, Hasegawa

WEKO 999475

en Shin, Hasegawa

Search repository
Akihiro, Hiroki

× Akihiro, Hiroki

WEKO 999476

en Akihiro, Hiroki

Search repository
Yasunari, Maekawa

× Yasunari, Maekawa

WEKO 999477

en Yasunari, Maekawa

Search repository
抄録
内容記述タイプ Abstract
内容記述 The effect of crosslinking on the thermal stability of poly (styrenesulfonic acid)-grafted poly (ether ether ketone) polymer electrolyte membranes (PEEK-PEMs) was investigated in water at 120 °C. The radiation-induced graft polymerization of an ethyl 4-styrenesulfonate (ETSS) monomer onto PEEK substrates, with divinylbenzene (DVB) (0.05, 0.1, 0.2, and 0.5wt.%) as a crosslinker, followed by hydrolysis, generated crosslinker-containing PEEK-PEMs (PEEK-×0.05, -×0.1, -×0.2, and -×0.5), because the crosslinker (up to 0.5wt.%) did not cause any destructive effect on the on grafting and hydrolysis rates. As a result, grafting degrees of 100–114% and ion exchange capacities (IECs) of 2.2–2.7 mmol/g, respectively, were achieved. Increasing the DVB amounts (from 0 to 0.5 wt.%), the conductivity, and water uptakes decreased; the PEEK-×0.5 showed a conductivity of 0.10 S/cm and water uptake of 43%. This confirms the successful incorporation of crosslinking structures on the graft-polymers. The hydrothermal test involved the immersion of PEMs in water at 120 °C for 500 hours. The no-crosslinked PEEK-PEMs with the same IEC (2.7 mmol/g) experienced a decreases in the weight and IEC to 84 and 68% levels from the initial values, respectively, while those of crosslinked PEEK-×0.05 almost maintained their initial values (100 and 96%, respectively). These results indicated that very small amounts of crosslinkers can decreases the conductivity and the water absorption tendency while increasing the hydrothermal stability at higher temperatures.
書誌情報 Radiation Physics and Chemistry

巻 171, p. 108647, 発行日 2019-12
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0969-806X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radphyschem.2019.108647
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0969806X19312216
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:32:35.463224
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3