WEKO3
アイテム
Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment.
https://repo.qst.go.jp/records/78030
https://repo.qst.go.jp/records/7803075860b53-470c-498d-97f3-1663adcd79fa
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-12-17 | |||||
タイトル | ||||||
タイトル | Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Matsumoto, Shinnosuke
× Matsumoto, Shinnosuke× Yonai, Shunsuke× E Bolch, Wesley× Shinnosuke, Matsumoto× Shunsuke, Yonai |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: To estimate out-of-field doses during carbon-ion radiotherapy (CIRT) for pediatric cerebellar ependymoma. METHODS: Given that the out-of-field dose of CIRT depends on beam parameters, we set them for treatment of typical pediatric cerebellar ependymoma based on a previous study. The out-of-field dose during CIRT for pediatric cerebellar ependymoma was then estimated using the Particle and Heavy-Ion Transport code System with Monte Carlo simulations and a computational phantom developed at the University of Florida. From the simulation results, out-of-field doses at dose equivalents of passive beam and active scanning beam CIRT were calculated and compared to the secondary neutron-equivalent dose of passive beam CIRT and proton therapy. RESULTS: The out-of-field dose equivalent decreases from 1.45 mSv/Gy (relative biological effectiveness - RBE) at the thyroid to 0.06 mSv/Gy (RBE) at the bladder, verifying decay as the distance from the treatment target increases. The out-of-field neutron-equivalent dose in organs per prescribed dose for passive beam CIRT is lower than that for passive beam proton therapy. Moreover, the out-of-field organ dose equivalent per prescribed dose for the active scanning beam CIRT is lower than that for the passive beam CIRT. CONCLUSIONS: Active scanning beam CIRT is promising for pediatric cerebellar ependymoma regarding out-of-field exposure, outperforming the comparison radiotherapy modalities. |
|||||
書誌情報 |
Medical physics 巻 46, 号 12, p. 5824-5832, 発行日 2019-12 |
|||||
出版者 | ||||||
出版者 | John Wiley and Sons, Inc. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-2405 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 31603561 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/mp.13864 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/mp.13864 |