WEKO3
アイテム
Analysis of peak heat load on the blanket module for JA DEMO
https://repo.qst.go.jp/records/77781
https://repo.qst.go.jp/records/777814c180748-ac35-4f46-8d32-345187ee0d66
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-12-03 | |||||
タイトル | ||||||
タイトル | Analysis of peak heat load on the blanket module for JA DEMO | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Miyoshi, Yuuya
× Miyoshi, Yuuya× Hiwatari, Ryoji× Someya, Yoji× Tokunaga, Shinsuke× Homma, Yuuki× Asakura, Nobuyuki× Sakamoto, Yoshiteru× Tobita, Kenji× Yuuya, Miyoshi× Ryoji, Hiwatari× Yoji, Someya× Shinsuke, Tokunaga× Yuuki, Homma× Nobuyuki, Asakura× Yoshiteru, Sakamoto× Kenji, Tobita |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Plasma heat flux in the peripheral plasma reaches the first wall (FW) along a magnetic field line, and it sometimes causes several MW/m2 orders of magnitude high heat flux concentration at narrow region, such as the edge of the blanket module. Thus, to assess and to reduce the heat load is key issue in the DEMO design activity. In this research, a new heat load analysis code is introduced based on the e-folding model. In this code, the decay length λ is changed depending on wall connection length of magnetic field line (defined as the length of magnetic field line from the wall to the wall), and parallel heat flux q// is calculated in each flux tube. This code can calculate the FW heat load simulating actual blanket module shapes. The 0.23 MW/m2 peak heat load at inner midplane in the case of the ideal FW (without gaps between blanket modules) is increased to 22 MW/m2 at toroidal module edge in the case of box shaped module. To shadow the edge and reduce such peak heat load, toroidal, and poloidal roof shaping is applied. Required roof height is analyzed from this code calculation. After shaping, peak heat load is reduced to 1.2 MW/m2. This value is under the allowable value 1.5 MW/m2, and in this case, surface temperature is also less than allowable temperature. | |||||
書誌情報 |
Fusion Engineering and Design 巻 151, p. 111394, 発行日 2020-02 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0920-3796 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.fusengdes.2019.111394 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0920379619308907 |