WEKO3
アイテム
Impact of additional plasma heating on detached plasma formation in divertor simulation experiments using the GAMMA 10/PDX tandem mirror
https://repo.qst.go.jp/records/77560
https://repo.qst.go.jp/records/7756017111191-dc85-45ba-936a-04d3287a5352
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-21 | |||||
タイトル | ||||||
タイトル | Impact of additional plasma heating on detached plasma formation in divertor simulation experiments using the GAMMA 10/PDX tandem mirror | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nakashima, Y.
× Nakashima, Y.× Islam, M.S.× Iijima, T.× Sakamoto, M.× Ezumi, N.× M.Yoshikawa× Asakura, Nobuyuki× Fukumoto, Masakatsu× Hatayama, A.× Hirata, M.× Ichimura, M.× Ikezoe, R.× Imai, T.× Islam, M.M.× Kariya, T.× Kohagura, J.× Masuzaki, S.× Minami, R.× Nakano, T.× Nojiri, K.× Numakura, T.× Sawada, K.× Shoji, M.× Terakado, A.× Togo, S.× Yamashita, S.× Yoshimoto, T.× Nobuyuki, Asakura× Masakatsu, Fukumoto |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The transition of a detached to attached plasma experiment has been performed in GAMMA 10/PDX by applying an additional plasma heating pulse of electron cyclotron heating (ECH). In a plasma detachment experiment, a short pulse (25 ms) of ECH was applied at the east plug-cell to examine the effects of electron heating on the plasma parameters in the D-module. It was found that the ion flux increased significantly during ECH injection. In the ECH injection period, the ion flux increased with the increasing impurity injection, which indicates the impurity ion components are enhanced by ionization in the D-module due to the application of ECH. During ECH injection period, the increase of the ion flux near the corner of the target plate shows a clear dependence on the gas species. The 2D visible emission has been captured by the high-speed camera and a bright emission near the corner of the target has been observed. The spectroscopic measurement in the D-module shows that the impurity ion emission increases remarkably during ECH injection. These results indicate the detached plasma change to the attached state. | |||||
書誌情報 |
Nuclear Materials and Energy 巻 18, p. 216-221, 発行日 2019-01 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2352-1791 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nme.2018.12.033 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S2352179118302564 |