ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

High LET Radiation Overcomes In Vitro Resistance to X-Rays of Chondrosarcoma Cell Lines

https://repo.qst.go.jp/records/77515
https://repo.qst.go.jp/records/77515
8dc22c4f-e690-4404-9c97-89e2ba3652a0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-11-20
タイトル
タイトル High LET Radiation Overcomes In Vitro Resistance to X-Rays of Chondrosarcoma Cell Lines
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Chevalier, Francois

× Chevalier, Francois

WEKO 1000198

Chevalier, Francois

Search repository
Dounia Houria Hamdi

× Dounia Houria Hamdi

WEKO 1000199

Dounia Houria Hamdi

Search repository
Charlotte Lepleux

× Charlotte Lepleux

WEKO 1000200

Charlotte Lepleux

Search repository
Temelie, Mihaela

× Temelie, Mihaela

WEKO 1000201

Temelie, Mihaela

Search repository
Anaıs Nicol

× Anaıs Nicol

WEKO 1000202

Anaıs Nicol

Search repository
Baptiste Austry, Jean

× Baptiste Austry, Jean

WEKO 1000203

Baptiste Austry, Jean

Search repository
Lesueur, Paul

× Lesueur, Paul

WEKO 1000204

Lesueur, Paul

Search repository
Vares, Guillaume

× Vares, Guillaume

WEKO 1000205

Vares, Guillaume

Search repository
Savu, Diana

× Savu, Diana

WEKO 1000206

Savu, Diana

Search repository
Nakajima, Tetsuo

× Nakajima, Tetsuo

WEKO 1000207

Nakajima, Tetsuo

Search repository
Saintigny, Yannick

× Saintigny, Yannick

WEKO 1000208

Saintigny, Yannick

Search repository
Tetsuo, Nakajima

× Tetsuo, Nakajima

WEKO 1000209

en Tetsuo, Nakajima

Search repository
抄録
内容記述タイプ Abstract
内容記述 Chondrosarcomas are malignant tumors of the cartilage that are chemoresistant and radioresistant to X-rays. This restricts the treatment options essential to surgery. In this study, we investigated the sensitivity of chondrosarcoma to X-rays and C-ions in vitro. The sensitivity of 4 chondrosarcoma cell lines (SW1353, CH2879, OUMS27, and L835) was determined by clonogenic survival assays and cell cycle progression. In addition, biomarkers of DNA damage responses were analyzed in the SW1353 cell line. Chondrosarcoma cells showed a heterogeneous sensitivity toward irradiation. Chondrosarcoma cell lines were more sensitive to C-ions exposure compared to X-rays. Using D10 values, the relative biological effectiveness of C-ions was higher (relative biological effectiveness ¼ 5.5) with cells resistant to X-rays (CH2879) and lower (relative biological effectiveness ¼ 3.7) with sensitive cells (L835). C-ions induced more G2 phase blockage and micronuclei in SW1353 cells as compared to X-rays with the same doses. Persistent unrepaired DNA damage was also higher following C-ions irradiation. These results indicate that chondrosarcoma cell lines displayed a heterogeneous response to conventional radiation treatment; however, treatment with C-ions irradiation was more efficient in killing chondrosarcoma cells, compared to X-rays.
書誌情報 Technology in Cancer Research & Treatment

巻 18, p. 1-11, 発行日 2019-11
出版者
出版者 SAGE publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 1533-0346
DOI
識別子タイプ DOI
関連識別子 10.1177/1533033819871309
関連サイト
識別子タイプ URI
関連識別子 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6732854/
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:31:50.898665
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3