WEKO3
アイテム
High LET Radiation Overcomes In Vitro Resistance to X-Rays of Chondrosarcoma Cell Lines
https://repo.qst.go.jp/records/77515
https://repo.qst.go.jp/records/775158dc22c4f-e690-4404-9c97-89e2ba3652a0
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-20 | |||||
タイトル | ||||||
タイトル | High LET Radiation Overcomes In Vitro Resistance to X-Rays of Chondrosarcoma Cell Lines | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Chevalier, Francois
× Chevalier, Francois× Dounia Houria Hamdi× Charlotte Lepleux× Temelie, Mihaela× Anaıs Nicol× Baptiste Austry, Jean× Lesueur, Paul× Vares, Guillaume× Savu, Diana× Nakajima, Tetsuo× Saintigny, Yannick× Tetsuo, Nakajima |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Chondrosarcomas are malignant tumors of the cartilage that are chemoresistant and radioresistant to X-rays. This restricts the treatment options essential to surgery. In this study, we investigated the sensitivity of chondrosarcoma to X-rays and C-ions in vitro. The sensitivity of 4 chondrosarcoma cell lines (SW1353, CH2879, OUMS27, and L835) was determined by clonogenic survival assays and cell cycle progression. In addition, biomarkers of DNA damage responses were analyzed in the SW1353 cell line. Chondrosarcoma cells showed a heterogeneous sensitivity toward irradiation. Chondrosarcoma cell lines were more sensitive to C-ions exposure compared to X-rays. Using D10 values, the relative biological effectiveness of C-ions was higher (relative biological effectiveness ¼ 5.5) with cells resistant to X-rays (CH2879) and lower (relative biological effectiveness ¼ 3.7) with sensitive cells (L835). C-ions induced more G2 phase blockage and micronuclei in SW1353 cells as compared to X-rays with the same doses. Persistent unrepaired DNA damage was also higher following C-ions irradiation. These results indicate that chondrosarcoma cell lines displayed a heterogeneous response to conventional radiation treatment; however, treatment with C-ions irradiation was more efficient in killing chondrosarcoma cells, compared to X-rays. | |||||
書誌情報 |
Technology in Cancer Research & Treatment 巻 18, p. 1-11, 発行日 2019-11 |
|||||
出版者 | ||||||
出版者 | SAGE publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1533-0346 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1177/1533033819871309 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6732854/ |