Commissioning of High Current H+/D+ ion beams for the Linear IFMIF Prototype Accelerator (LIPAc)

https://repo.qst.go.jp/records/77369
https://repo.qst.go.jp/records/77369
2b3abbb0-59bb-4497-97a0-ec444eef57e2
Item type 会議発表用資料 / Presentation(1)
公開日 2019-11-08
タイトル
タイトル Commissioning of High Current H+/D+ ion beams for the Linear IFMIF Prototype Accelerator (LIPAc)
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Akagi, Tomoya

× Akagi, Tomoya

WEKO 802646

Akagi, Tomoya

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 802647

Kasugai, Atsushi

Search repository
Kondo, Keitaro

× Kondo, Keitaro

WEKO 802648

Kondo, Keitaro

Search repository
Sakamoto, Keishi

× Sakamoto, Keishi

WEKO 802649

Sakamoto, Keishi

Search repository
Sugimoto, Masayoshi

× Sugimoto, Masayoshi

WEKO 802650

Sugimoto, Masayoshi

Search repository
Akagi, Tomoya

× Akagi, Tomoya

WEKO 802651

en Akagi, Tomoya

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 802652

en Kasugai, Atsushi

Search repository
Kondo, Keitaro

× Kondo, Keitaro

WEKO 802653

en Kondo, Keitaro

Search repository
Sakamoto, Keishi

× Sakamoto, Keishi

WEKO 802654

en Sakamoto, Keishi

Search repository
Sugimoto, Masayoshi

× Sugimoto, Masayoshi

WEKO 802655

en Sugimoto, Masayoshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The Linear IFMIF (International Fusion Materials Irradiation Facility) Prototype Accelerator (LIPAc) is aiming at demonstration of the low energy section of 40 MeV/125 mA IFMIF deuteron accelerator up to 9 MeV with a full beam current in continuous wave (CW). For such high-power beam, the LIPAc injector is required to produce a 100 keV D+ beam with 140 mA. The injector is composed of the ECR ion source based on the CEA-Saclay SILHI source and a Low Energy Beam Transport (LEBT) line. The capability of the injector to produce 100 keV/140 mA D+ beam with emittance of 0.25 π mm mrad has already been demonstrated by 2017. The H+ beam with half energy and half current with respect to the nominal D+ beam is also used at the initial phase of the beam commissioning of the 175 MHz, 5 MeV Radio Frequency Quadrupole (RFQ). In 2019, the commissioning of the RFQ to demonstrate the D+ beam acceleration at low duty cycle (0.1%) is being implemented. This paper describes the latest results obtained through the efforts to characterize the pulsed D+ beam as well as H+ beam extracted from injector. The progress of demonstration of high current D+ beam acceleration will be also presented.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 18th International Conference on Ion Sources (ICIS’19)
発表年月日
日付 2019-09-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:37:02.730506
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3