ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Retrieving Beam Current Waveforms from ACCT Output Using Experimental Response Function for use in Long Pulse Accelerators

https://repo.qst.go.jp/records/77302
https://repo.qst.go.jp/records/77302
023799e1-05d7-4a83-82ef-dd37085e0378
Item type 会議発表用資料 / Presentation(1)
公開日 2019-11-05
タイトル
タイトル Retrieving Beam Current Waveforms from ACCT Output Using Experimental Response Function for use in Long Pulse Accelerators
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirata, Yosuke

× Hirata, Yosuke

WEKO 797742

Hirata, Yosuke

Search repository
hirata

× hirata

WEKO 797743

hirata

Search repository
Franco Campos, Jose

× Franco Campos, Jose

WEKO 797744

Franco Campos, Jose

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 797745

Kasugai, Atsushi

Search repository
Hirata, Yosuke

× Hirata, Yosuke

WEKO 797746

en Hirata, Yosuke

Search repository
Franco Campos, Jose

× Franco Campos, Jose

WEKO 797747

en Franco Campos, Jose

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 797748

en Kasugai, Atsushi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Current transformers (ACCT/DCCT) are used as non-interceptive means of beam current measurement in many accelerators. In the case of long pulse to CW accelerators for fusion neutron sources such as IFMIF, A-FNS, etc., current measurement using current transformers for pulses with around 10-100 ms or longer suffer such problems as drooping and the measurement accuracy is deteriorated. So, improving the accuracy for long pulse beams is highly required. We have proposed a method for retrieving the beam currents from the ACCT output using the transfer function obtainable from simple experiments. It was confirmed from numerical calculation that beam currents longer than a second could be theoretically retrieved*. The effects of associated circuits and cables such as stray capacitance, inductance and magnetic materials nearby are inherently included in the transfer function. We are working for implementing this method into FPGA. For calculation convenience, the transfer function is converted into a form of impulse function and the convolution with the digitized ACCT output is to be carried out to retrieve the beam current. The theory, algorithm and design will be discussed. (1194 letters)
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 IBIC 2019, International Beam Instrumentation
発表年月日
日付 2019-09-09
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:39:21.496460
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3