RETRIEVING BEAM CURRENT WAVEFORMS FROM ACCT OUTPUT USING EXPERIMENTAL RESPONSE FUNCTION FOR USE IN LONG PULSE ACCELERATORS

https://repo.qst.go.jp/records/77301
https://repo.qst.go.jp/records/77301
e649c18a-07cc-40b0-8847-d0bb939e7da7
Item type 会議発表論文 / Conference Paper(1)
公開日 2019-11-05
タイトル
タイトル RETRIEVING BEAM CURRENT WAVEFORMS FROM ACCT OUTPUT USING EXPERIMENTAL RESPONSE FUNCTION FOR USE IN LONG PULSE ACCELERATORS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirata, Yosuke

× Hirata, Yosuke

WEKO 996329

Hirata, Yosuke

Search repository
hirata

× hirata

WEKO 996330

hirata

Search repository
Franco Campos, Jose

× Franco Campos, Jose

WEKO 996331

Franco Campos, Jose

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 996332

Kasugai, Atsushi

Search repository
Yosuke, Hirata

× Yosuke, Hirata

WEKO 996333

en Yosuke, Hirata

Search repository
Franco Campos, Jose

× Franco Campos, Jose

WEKO 996334

en Franco Campos, Jose

Search repository
Atsushi, Kasugai

× Atsushi, Kasugai

WEKO 996335

en Atsushi, Kasugai

Search repository
抄録
内容記述タイプ Abstract
内容記述 Current transformers (ACCT/DCCT) are used as non-interceptive means of beam current measurement in many accelerators. In the case of long pulse to CW accelerators for fusion neutron sources such as IFMIF, A-FNS, etc., current measurement using current transformers for pulses with around 10-100 ms or longer suffer such problems as drooping and the measurement accuracy is deteriorated. So, improving the accuracy for long pulse beams is high-ly required. We have proposed a method for retrieving the beam currents from the ACCT output using a transfer function obtainable from simple experiments. It was confirmed from numerical calculation that beam currents longer than a second could be theoretically retrieved. The effects of associated circuits and cables such as stray capacitance, inductance and magnetic materials nearby are inherently included in the transfer function. We are working for implementing this method into FPGA. For calculation convenience, the transfer function is convert-ed into a form of impulse response function and the con-volution with the digitized ACCT output is to be carried out to retrieve the beam current. The theory, algorithm and design will be discussed.
書誌情報 Proceedings of the 8th International Beam Instrumentation Conference

発行日 2019-09
DOI
識別子タイプ DOI
関連識別子 10.18429/JACoW-IBIC2019-MOPP009
関連サイト
識別子タイプ URI
関連識別子 http://ibic2019.vrws.de/
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:35:59.824131
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3