ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

DOI vs. TOF: performance comparison of two helmet-type PET prototypes based on the NEMA NU2 standards

https://repo.qst.go.jp/records/77293
https://repo.qst.go.jp/records/77293
6e9d4c94-e950-441a-9788-a1f18eeaa4c4
Item type 会議発表用資料 / Presentation(1)
公開日 2019-10-02
タイトル
タイトル DOI vs. TOF: performance comparison of two helmet-type PET prototypes based on the NEMA NU2 standards
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Akamatsu, Go

× Akamatsu, Go

WEKO 797527

Akamatsu, Go

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 797528

Yoshida, Eiji

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 797529

Tashima, Hideaki

Search repository
Iwao, Yuma

× Iwao, Yuma

WEKO 797530

Iwao, Yuma

Search repository
Wakizaka, Hidekatsu

× Wakizaka, Hidekatsu

WEKO 797531

Wakizaka, Hidekatsu

Search repository
Maeda, Takamasa

× Maeda, Takamasa

WEKO 797532

Maeda, Takamasa

Search repository
Takahashi, Miwako

× Takahashi, Miwako

WEKO 797533

Takahashi, Miwako

Search repository
Yamashita, Taichi

× Yamashita, Taichi

WEKO 797534

Yamashita, Taichi

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 797535

Yamaya, Taiga

Search repository
Akamatsu, Go

× Akamatsu, Go

WEKO 797536

en Akamatsu, Go

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 797537

en Yoshida, Eiji

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 797538

en Tashima, Hideaki

Search repository
Iwao, Yuma

× Iwao, Yuma

WEKO 797539

en Iwao, Yuma

Search repository
Wakizaka, Hidekatsu

× Wakizaka, Hidekatsu

WEKO 797540

en Wakizaka, Hidekatsu

Search repository
Maeda, Takamasa

× Maeda, Takamasa

WEKO 797541

en Maeda, Takamasa

Search repository
Takahashi, Miwako

× Takahashi, Miwako

WEKO 797542

en Takahashi, Miwako

Search repository
Yamashita, Taichi

× Yamashita, Taichi

WEKO 797543

en Yamashita, Taichi

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 797544

en Yamaya, Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 Brain PET imaging plays key roles in neurology, neuro-oncology, and molecular imaging research fields. To fulfill a growing demand for a high-sensitivity, high-resolution, low-cost and compact brain PET system, we have proposed a helmet-shape detector arrangement. In the 2016 conference, we described development of the first prototype, which had depth-of-interaction (DOI) detectors without time-of-flight (TOF) capability. Last year, we reported the second prototype which had TOF capability of a 245-ps coincidence timing resolution without DOI capability. The crystal thickness was optimized through simulation so as to reduce the parallax error while keeping the gain in image quality. The detector was composed of 12×12 lutetium fine silicate (LFS) scintillation crystals (4×4×10 mm3) connected to a 12×12 multi-pixel photon counter (MPPC) array with one-to-one coupling. In this work, we have evaluated performance of the second prototype based on the NEMA NU2 standards and compared the results with those of the first prototype. The values measured with the first (DOI) and second (TOF) prototypes were: spatial resolutions of 2.8 and 4.3 mm at the central position (1-cm offset) by the filtered back-projection method; sensitivities of 13.4 and 4.1 kcps/MBq; scatter fractions at the low activity of 31% and 31%; and peak noise-equivalent count rates (NECR) of 20.0 kcps at 2.6 kBq/mL and 18.6 kcps at 9.0 kBq/mL. With a TOF sensitivity gain of 5.4 (= 20 cm diameter / 3.675 cm TOF localization), effective sensitivity and effective peak NECR were 22.3 kcps/MBq and 101.2 kcps at 9.0 kBq/mL for the second prototype. In the image quality assessment, the second prototype outperformed the first prototype. Although the first prototype had better performance for spatial resolution and sensitivity themselves which were measured with low count rate, the TOF capability of the second prototype worked well to reduce the random ratio, which resulted in the superior image quality.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
発表年月日
日付 2019-10-30
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:39:25.570672
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3