A Single-Ended Readout 4-Lyer DOI Detector with a 1 mm Crystal Pitch for Small Animal PET Imaging

https://repo.qst.go.jp/records/77149
https://repo.qst.go.jp/records/77149
bafd9575-5575-4615-9f2e-c8ae3f9cde4a
Item type 会議発表用資料 / Presentation(1)
公開日 2019-10-16
タイトル
タイトル A Single-Ended Readout 4-Lyer DOI Detector with a 1 mm Crystal Pitch for Small Animal PET Imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kang, Hangyu

× Kang, Hangyu

WEKO 793882

Kang, Hangyu

Search repository
Obata, Fujino

× Obata, Fujino

WEKO 793883

Obata, Fujino

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 793884

Tashima, Hideaki

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 793885

Nishikido, Fumihiko

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 793886

Yamaya, Taiga

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 793887

en Kang, Hangyu

Search repository
Obata, Fujino

× Obata, Fujino

WEKO 793888

en Obata, Fujino

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 793889

en Tashima, Hideaki

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 793890

en Nishikido, Fumihiko

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 793891

en Yamaya, Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 In a previous study, we developed a 4-layer depth-of-interaction (DOI) detector with 1.5 mm crystals for organ-dedicated PET application. However, the crystal size was not appropriate for submillimeter small animal imaging. The aim of this study was to develop a 4-layer DOI detector with a 1 mm crystal pitch to develop a submillimeter resolution small animal PET scanner. The proposed 4-layer DOI detector consisted of an 8 × 8 LYSO crystal array (1 × 1 × 5 mm3) stacked in 4 layers which yielded a total thickness of 20 mm, an acrylic light guide (13 × 13 × 1 mm3), and a 4×4 SiPM array (S13361-3050NE-04, Hamamatsu Photonics, Japan) with a pixel pitch of 3.2 mm. The DOI information was encoded into a 2D flood histogram by using the combination of an enhanced specular reflector and room temperature vulcanized (RTV) rubber on the side surface of the LYSO crystal. Sixteen SiPM output signals were multiplexed into four positional signals (A, B, C, and D) using a charge division circuit, and then digitized by using CAMAC DAQ. A 22Na point source was used to irradiate 511 keV gamma photons to the LYSO crystal array. The 4-layer DOI information could be encoded into the 2D flood histogram with a crystal identification rate of 89% based on the visual check. The energy resolutions of the 1st, 2nd, 3rd, and 4th layers were 11%, 15%, 13%, and 32%, respectively. In conclusion, we developed a single-ended readout 4-layer DOI detector with a 1 mm LYSO pitch and total thickness of 20 mm. In the future, we plan to improve the crystal identification rate further to 100% by optimizing the reflector material and light guide design. After the optimization of the detector performance, we will develop a prototype small animal PET scanner for submillimeter high-resolution and high-sensitivity preclinical molecular imaging.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2019-10-31
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:40:40.577822
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3