ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Verification of accuracy of contact-probe distance meter for lithium target of fusion neutron source

https://repo.qst.go.jp/records/77105
https://repo.qst.go.jp/records/77105
ba742abf-fb6e-40cd-9a88-709230d0c490
Item type 会議発表用資料 / Presentation(1)
公開日 2019-10-09
タイトル
タイトル Verification of accuracy of contact-probe distance meter for lithium target of fusion neutron source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 沖田, 隆文

× 沖田, 隆文

WEKO 882800

沖田, 隆文

Search repository
圓谷, 彰太

× 圓谷, 彰太

WEKO 882801

圓谷, 彰太

Search repository
渡辺, 鴻太郎

× 渡辺, 鴻太郎

WEKO 882802

渡辺, 鴻太郎

Search repository
東, 雅博

× 東, 雅博

WEKO 882803

東, 雅博

Search repository
帆足, 英二

× 帆足, 英二

WEKO 882804

帆足, 英二

Search repository
近藤, 浩夫

× 近藤, 浩夫

WEKO 882805

近藤, 浩夫

Search repository
Park, ChangHo

× Park, ChangHo

WEKO 882806

Park, ChangHo

Search repository
Nakamura, Makoto

× Nakamura, Makoto

WEKO 882807

Nakamura, Makoto

Search repository
Ochiai, Kentaro

× Ochiai, Kentaro

WEKO 882808

Ochiai, Kentaro

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 882809

Kasugai, Atsushi

Search repository
Park, ChangHo

× Park, ChangHo

WEKO 882810

en Park, ChangHo

Search repository
Nakamura, Makoto

× Nakamura, Makoto

WEKO 882811

en Nakamura, Makoto

Search repository
Ochiai, Kentaro

× Ochiai, Kentaro

WEKO 882812

en Ochiai, Kentaro

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 882813

en Kasugai, Atsushi

Search repository
抄録
内容記述タイプ Abstract
内容記述 An accelerator based intense neutron sources such as the IFMIF, A-FNS and DONES produce neutron flux by a stripping reaction between lithium (Li) and deuteron for testing various materials for fusion reactor. In these fusion neutron sources, a liquid Li free-surface jet is applied as the liquid Li target. For the development of the Li target system, the variation in the thickness of the Li jet was measured using the Li loop of Osaka University. At the Osaka Univ., a lot of knowledge about the surface fluctuation of the Li jet had been obtained by using the electro-contact type distance meter (referred to as the probe apparatus herein). Besides, for the stable and safety operation of the facility, the probe apparatus is planned to be used as a safety interlock system for beam irradiation in actual intense neutron source because of its simple structure. Therefore, it is desirable to verify its accuracy. Especially, it is expected that false detections and undetected waves, which is particular to the contact-type apparatus, could cause errors. Then in this study, the measurement using non-contact type distance meter using optical comb (referred to as the laser probe herein) was conducted, and then the error of the results of probe apparatus is evaluated by comparing results.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 14th International Symposium on Fusion Nuclear Technology
発表年月日
日付 2019-09-26
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:03:09.098161
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3