ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Imaging of 99mTc-DMSA and 18F-FDG in Humans Using a Si/CdTe Compton Camera

https://repo.qst.go.jp/records/77069
https://repo.qst.go.jp/records/77069
3b37c64d-c8e1-4a71-bf38-8e36a0c7994c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-06-25
タイトル
タイトル Imaging of 99mTc-DMSA and 18F-FDG in Humans Using a Si/CdTe Compton Camera
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakano, Takashi

× Nakano, Takashi

WEKO 1004899

Nakano, Takashi

Search repository
Makoto, Sakai (Gunma Univ.)

× Makoto, Sakai (Gunma Univ.)

WEKO 1004900

Makoto, Sakai (Gunma Univ.)

Search repository
Kota, Torikai (Gunma Univ.)

× Kota, Torikai (Gunma Univ.)

WEKO 1004901

Kota, Torikai (Gunma Univ.)

Search repository
Yoshiyuki, Suzuki (Gunma Univ.)

× Yoshiyuki, Suzuki (Gunma Univ.)

WEKO 1004902

Yoshiyuki, Suzuki (Gunma Univ.)

Search repository
Shin-ei, Noda (Saitama Medical Univ.)

× Shin-ei, Noda (Saitama Medical Univ.)

WEKO 1004903

Shin-ei, Noda (Saitama Medical Univ.)

Search repository
Yamaguchi, Mitsutaka

× Yamaguchi, Mitsutaka

WEKO 1004904

Yamaguchi, Mitsutaka

Search repository
Shin'ichiro, Takeda (OIST)

× Shin'ichiro, Takeda (OIST)

WEKO 1004905

Shin'ichiro, Takeda (OIST)

Search repository
Nagao, Yuuto

× Nagao, Yuuto

WEKO 1004906

Nagao, Yuuto

Search repository
Mikiko, Kikuchi (Gunma Univ.)

× Mikiko, Kikuchi (Gunma Univ.)

WEKO 1004907

Mikiko, Kikuchi (Gunma Univ.)

Search repository
Hirokazu, Odaka (JAXA)

× Hirokazu, Odaka (JAXA)

WEKO 1004908

Hirokazu, Odaka (JAXA)

Search repository
Tomihiro, Kamiya (Gunma Univ.)

× Tomihiro, Kamiya (Gunma Univ.)

WEKO 1004909

Tomihiro, Kamiya (Gunma Univ.)

Search repository
Kawachi, Naoki

× Kawachi, Naoki

WEKO 1004910

Kawachi, Naoki

Search repository
Shin, Watanabe (JAXA)

× Shin, Watanabe (JAXA)

WEKO 1004911

Shin, Watanabe (JAXA)

Search repository
Kazuo, Arakawa (Gunma Univ.)

× Kazuo, Arakawa (Gunma Univ.)

WEKO 1004912

Kazuo, Arakawa (Gunma Univ.)

Search repository
Tadayuki, Takahashi (JAXA)

× Tadayuki, Takahashi (JAXA)

WEKO 1004913

Tadayuki, Takahashi (JAXA)

Search repository
Takashi, Nakano

× Takashi, Nakano

WEKO 1004914

en Takashi, Nakano

Search repository
Mitsutaka, Yamaguchi

× Mitsutaka, Yamaguchi

WEKO 1004915

en Mitsutaka, Yamaguchi

Search repository
Yuuto, Nagao

× Yuuto, Nagao

WEKO 1004916

en Yuuto, Nagao

Search repository
Naoki, Kawachi

× Naoki, Kawachi

WEKO 1004917

en Naoki, Kawachi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The Compton camera can simultaneously acquire images of multiple isotopes injected in a body; therefore, it has the potential to introduce a new subfield in the field of biomedical imaging applications. The objective of this study is to assess the ability of a prototype semiconductor-based silicon/cadmium telluride (Si/CdTe) Compton camera to simultaneously image the distributions of technetium (99mTc)-dimercaptosuccinic acid (DMSA) (141 keV emission) and 18F-fluorodeoxyglucose (FDG) (511 keV emission) injected into a human volunteer. 99mTc-DMSA and 18F-FDG were injected intravenously into a 25-year-old male volunteer. The distributions of 99mTc-DMSA and 18F-FDG were simultaneously made visible by setting a specified energy window for each radioisotope. The images of these radiopharmaceuticals acquired using the prototype Compton camera were superimposed onto computed tomography images for reference. The reconstructed image showed that 99mTc-DMSA had accumulated in both kidneys, which is consistent with the well-known diagnostic distribution determined by clinical imaging via single-photon emission computed tomography. In the 18F-FDG image, there is broad distribution around the liver and kidneys, which was expected based on routine clinical positron emission tomography imaging. The current study demonstrated for the first time that the Si/CdTe Compton camera was capable of simultaneously imaging the distributions of two radiopharmaceuticals, 99mTc-DMSA and 18F-FDG, in a human body. These results suggest that the Si/CdTe Compton camera has the potential to become a novel modality for nuclear medical diagnoses enabling multi-probe simultaneous tracking.
書誌情報 Physics in Medicine & Biology

巻 65, 号 5, p. 05LT01, 発行日 2019-07
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ab33d8
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1088/1361-6560/ab33d8
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:27:15.123875
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3