ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Dose estimation of electrons and positrons from 64Cu using fluorescence nuclear track detector

https://repo.qst.go.jp/records/76948
https://repo.qst.go.jp/records/76948
5c49cfc5-9a9d-47a0-9bda-c5b77875a54d
Item type 会議発表用資料 / Presentation(1)
公開日 2019-09-27
タイトル
タイトル Dose estimation of electrons and positrons from 64Cu using fluorescence nuclear track detector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 楠本, 多聞

× 楠本, 多聞

WEKO 786581

楠本, 多聞

Search repository
小平聡

× 小平聡

WEKO 786582

小平聡

Search repository
Fromm, Michel

× Fromm, Michel

WEKO 786583

Fromm, Michel

Search repository
Omar, Norhan

× Omar, Norhan

WEKO 786584

Omar, Norhan

Search repository
長谷川純崇

× 長谷川純崇

WEKO 786585

長谷川純崇

Search repository
小川原亮

× 小川原亮

WEKO 786586

小川原亮

Search repository
小西輝昭

× 小西輝昭

WEKO 786587

小西輝昭

Search repository
甲斐健師

× 甲斐健師

WEKO 786588

甲斐健師

Search repository
Kusumoto, Tamon

× Kusumoto, Tamon

WEKO 786589

en Kusumoto, Tamon

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background and Objectives
Recently, radiation therapies have been recognized as effective candidates for the cancer treatment. Among them, the targeted radioimmunotherapy using radiolabeled copper (Ⅱ) (diacetyl-bis N4-methylthiosemicarbazone) (64Cu-ATSM) is underdevelopment as a new generational cancer treatment 1). 64Cu decays by emission of β- (0.573 MeV), β+ (0.656 MeV) and electron capture (41%) with half-life of 12.7 h. The specific feature of 64Cu is the emission of auger electrons, which has been expected to be effective to kill cancer cells. The therapeutic effectiveness of 64Cu-ATSM for hypoxic cancer cells has been demonstrated so far but the absorbed dose from 64Cu has not been quantitatively evaluated. To establish a dose evaluation method of electrons, we, in the first step, have conducted the dosimetry of 64Cu.

Experiments
Fluorescence Nuclear Track Detector (FNTD) (Landauer, Ltd.) with a thickness of 90 μm was employed for the dosimetry. The fluorescence intensities were measured using confocal laser scanning microscope (FV-1000, Olympus Co.). FNTD was excited by a laser with a wavelength of 635 nm and then we read the luminescence intensity at 668 nm.
An aqueous copper nitrate solution (FUJIFILM), which was labeled by 64Cu, was used as an electrons source. The radioactivity was 684 kBq at 10:30 on December 20th, 2018. We removed aqueous copper nitrate solution at 13:00 on January 28th, 2019.

Results and Discussion
Figure 1 shows the depth dependence of relative fluorescence intensity, that is proportional to the absorbed dose. Inset photos are confocal microscopic images of FNTD. The fluorescence intensity at deeper layer could be darker due to the optical light absorption of both excited and emitted lights. The changes in the intensity are calibrated by gamma exposures. The relative intensity decreases monotonically with increasing the depth. At 0 μm in depth, the high absorbed dose is predominantly attributed to auger electrons, characteristic X-rays, β- and β+. Furthermore, the continuous slowing down approximation range of β- in FNTD is 0.85 cm calculated by E-STAR program2). This implies that we should consider the influence to the normal tissues by β- and β+.

Conclusion
We clarified depth dependence of fluorescence intensity measured by FNTD. We are addressing to evaluate the 60Co equivalent dose in water at each depth. Additionally, the results obtained present work will be compared to that using a Monte Carlo simulation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 19th International Conference on Solid State Dosimetry
発表年月日
日付 2019-09-20
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:43:40.075384
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3