著者 |
Fujisaku, Takahiro
× Fujisaku, Takahiro× Tanabe, Ryotaro× Onoda, Shinobu× Kubota, Ryou× F. Segawa, Takuya× So, Frederick× Ohshima, Takeshi× Hamachi, Itaru× Shirakawa, Masahiro× Igarashi, Ryuji× Takahiro, Fujisaku× Shinobu, Onoda× So, Frederick× Takeshi, Ohshima× Masahiro, Shirakawa× Ryuji, Igarashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Nanoscale measurements provide insight into the nano world. For instance, nanometric spatiotemporal distribution of intracellular pH is regulated by and regulates a variety of biological processes. However, there is no general method to fabricate nanoscale pH sensors. Here, we, to endow pH-sensing functions, tailor the surface properties of a fluorescent nanodiamond (FND) containing nitrogen-vacancy centers (NV centers) by coating the FND with an ionic chemical layer. The longitudinal relaxation time T1 of the electron spins in the NV centers inside a nanodiamond modified by carboxyl groups on the particle surface was found to depend on ambient pH between pH 3 and pH 7, but not between pH 7 and pH 11. Therefore, a single particle of the carboxylated nanodiamond works as a nanometer-sized pH meter within a microscopic image and directly measures the nanometric local pH environment. Moreover, the pH dependence of an FND was changed by coating it with a polycysteine layer, which contains a multitude of thiol groups with higher pKa. The polycysteine-coated nanodiamond obtained a pH dependence between pH 7 and pH 11. The pH dependence of the FND was also observed in heavy water (D2O) buffers. This indicates that the pH dependence is not caused by magnetic noise induced by 1H nuclear spin fluctuations, but by electric noise induced by ion exchanges. Via our method, the sensitive pH range of the nanodiamond pH sensor can potentially be controlled by changing the ionic layer appropriately according to the target biological phenomena. |
|||||
書誌情報 |
ACS Nano 巻 13, 号 10, p. 11726-11732, 発行日 2019-09 |
|||||
出版者 | ||||||
出版者 | ACS Publications | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1936-0851 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1021/acsnano.9b05342 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://pubs.acs.org/doi/abs/10.1021/acsnano.9b05342 |