ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

24th International Conference on Medical Physics 発表

https://repo.qst.go.jp/records/76826
https://repo.qst.go.jp/records/76826
505d1fea-5f90-4984-9820-05ae4dcbb8b4
Item type 会議発表用資料 / Presentation(1)
公開日 2019-09-18
タイトル
タイトル 24th International Conference on Medical Physics 発表
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 784443

Matsufuji, Naruhiro

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 784444

en Matsufuji, Naruhiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 (Introduction)
As the best use of the Bragg curve nature, hypofractionated ion-beam therapy has been promoted on various tumor site. In carbon-ion therapy for prostate cancer treatment at the Heavy Ion Medical Accelerator in Chiba (HIMAC), radical hypofractionation has been performed by selectively reducing the urethral dose located at the center of the prostate tumor. It is needed there to establish an in-vivo dosimeter to confirm if the dose to urethra is surely reduced as planned during the therapeutic irradiation. This study investigated a response of a miniature sphere diode as a candidate for the in-vivo dosimeter for therapeutic carbon-ion beam.
(Material and Methods)
Sphere diode of 1.2 and 1.8mm in diameter made by Sphelar Power Co., Ltd. (Kyoto, Japan) was tested. The measurement was carried out at the therapeutic port of HIMAC with pristine 290 MeV/n of carbon beam as well as therapeutic 350 MeV/n spread-out Bragg peak (SOBP) beams. Output current from the diode during the irradiation was measured with an electrometer as integral charge. A pinpoint ionization chamber was also used for the sake of comparison.
(Result and Discussion)
The spherical geometry of silicon caused slight broadening or pristine Bragg peak of the carbon-ion beam, however, for SOBP beam it showed superior dosimetric response free from LET dependency as almost comparable as those measured with an ionization chamber. The measurement with the smaller diode successfully reproduced the decrease in dose at the middle of the SOBP intentionally designed to simulate the therapeutic irradiation reducing urethral dose. The diode showed decrease in sensitivity of about 1% / Gy as a function of integral dose, however, the output linearity on dose and subtle incident angular dependence together with the smallness and safeness make the silicon diode as a good candidate for the in-vivo dosimeter in ion-beam therapy.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 "RESPONSE OF A MINIATURE SPHERICAL DIODE AS A DOSIMETER FOR THERAPEUTIC CARBON-ION BEAM"にて発表を行う
発表年月日
日付 2019-09-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:44:31.431843
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3