Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry

https://repo.qst.go.jp/records/76800
https://repo.qst.go.jp/records/76800
eb178015-98ba-4f2a-87a7-72adbd87c5ba
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-09-17
タイトル
タイトル Trace determination of uranium preconcentrated using graphene oxide by total reflection X‐ray fluorescence spectrometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takahashi, Hiroaki

× Takahashi, Hiroaki

WEKO 997538

Takahashi, Hiroaki

Search repository
Izumoto, Yukie

× Izumoto, Yukie

WEKO 997539

Izumoto, Yukie

Search repository
Matsuyama, Tsugufumi

× Matsuyama, Tsugufumi

WEKO 997540

Matsuyama, Tsugufumi

Search repository
Yoshii, Hiroshi

× Yoshii, Hiroshi

WEKO 997541

Yoshii, Hiroshi

Search repository
Yukie, Izumoto

× Yukie, Izumoto

WEKO 997542

en Yukie, Izumoto

Search repository
Tsugufumi, Matsuyama

× Tsugufumi, Matsuyama

WEKO 997543

en Tsugufumi, Matsuyama

Search repository
Hiroshi, Yoshii

× Hiroshi, Yoshii

WEKO 997544

en Hiroshi, Yoshii

Search repository
抄録
内容記述タイプ Abstract
内容記述 A new method based on dispersive microsolid phase extraction using graphene oxide (GO) as a solid adsorbent and total reflection X‐ray fluorescence (TXRF) spectrometry is proposed for trace determination of uranium. In the developed methodology, a suspension of GO was injected into uranium‐spiked multielement solutions including rubidium; after filtration, the membrane filter with collected GO was placed in a small volume of internal standard acid solution and the eluent containing uranium was deposited onto a fluorine resin‐ coated slide glass, which is a disposable sample stage. Using GO was effective for removal of rubidium from the measurement solution to avoid interference between Rb Kα peak and U Lα peak. The high enrichment factor of 150 enables obtaining uranium detection limits of 0.042, 0.087, and 0.12 μg L−1 for ionic strength of 0.01, 0.1, and 1 mol L−1, respectively. Such low detection limits were obtained by using a benchtop TXRF spectrometer with 5‐min measurement. The proposed method is suitable for trace uranium determination in water, including high salinity samples.
書誌情報 X-ray spectrometry

巻 48, 号 5, p. 366-374, 発行日 2019-09
出版者
出版者 Wiley
ISSN
収録物識別子タイプ ISSN
収録物識別子 0049-8246
DOI
識別子タイプ DOI
関連識別子 10.1002/xrs.3032
関連サイト
識別子タイプ URI
関連識別子 https://onlinelibrary.wiley.com/doi/abs/10.1002/xrs.3032
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:34:39.593500
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3