ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Development of low-temperature fusion using ammonium hydrogen fluoride for rapid determination of actinides in environmental and nuclear decommissioning samples

https://repo.qst.go.jp/records/76748
https://repo.qst.go.jp/records/76748
20003a47-8b22-4a58-869b-a48e5c329061
Item type 会議発表用資料 / Presentation(1)
公開日 2019-09-11
タイトル
タイトル Development of low-temperature fusion using ammonium hydrogen fluoride for rapid determination of actinides in environmental and nuclear decommissioning samples
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zheng, Jian

× Zheng, Jian

WEKO 782727

Zheng, Jian

Search repository
Wang, Hai

× Wang, Hai

WEKO 782728

Wang, Hai

Search repository
Ni, Youyi

× Ni, Youyi

WEKO 782729

Ni, Youyi

Search repository
Huang, Zhaoya

× Huang, Zhaoya

WEKO 782730

Huang, Zhaoya

Search repository
Aono, Tatsuo

× Aono, Tatsuo

WEKO 782731

Aono, Tatsuo

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 782732

en Zheng, Jian

Search repository
Aono, Tatsuo

× Aono, Tatsuo

WEKO 782733

en Aono, Tatsuo

Search repository
抄録
内容記述タイプ Abstract
内容記述 In this study, a green and rapid analytical method was developed for determination of 237Np and Pu isotopes in environmental and nuclear decommissioning samples, such as soil, marine sediment and concrete samples. The methods consisted of NH4HF2 fusion incorporated with procedure for CaF2/LaF3 co-precipitation, extraction chromatography or anion-exchange chromatography and ICP-MS measurement. ICP-MS, as an atom-counting approach that counts the atoms themselves, irrespective of their decay mode, specific activity, or half-life, is gradually replacing/has replaced conventional radiometric methods, for ultra-sensitive analysis of actinides. The fusion procedure was done at 250oC on a portable hot plate instead of in a cumbersome muffle furnace and took only 15 min. Chemical recoveries of 237Np and Pu after completing the NH4HF2 fusion method and chromatographic separation for 0.5-1 g sample were approximately 70-90%. The NH4HF2 fusion was capable of completely releasing actinides from samples that were pre-ignited at temperatures over 450 oC to 1000 oC, which was comparable to releases obtained by the hazardous and time-consuming HNO3-HF digestion. Additionally, because HF is not used in any procedure of the NH4HF2 fusion, a safer and greener alternative to HNO3-HF digestion is realized for rapid 237Np and Pu isotopes determination in soil, marine sediment and concrete samples. It takes approximately one day for 10 sample analysis (NH4HF2 fusion and sample transferring, 0.5 h; CaF2/LaF3 coprecipitation and filtration, 1.5 h; chromatographic separation and sample preparation, 5.5 h; ICP-MS measurement, 0.5 h) which is less than the conventional acid digestion methods.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 日本分析化学会第68年会
発表年月日
日付 2019-09-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:45:08.917926
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3