Phase sensitive quantum magnetometry imaging using ensemble NV center in diamond on wide field optics

https://repo.qst.go.jp/records/76600
https://repo.qst.go.jp/records/76600
a08d086f-96a7-4830-b616-05208bb029fa
Item type 会議発表用資料 / Presentation(1)
公開日 2019-08-29
タイトル
タイトル Phase sensitive quantum magnetometry imaging using ensemble NV center in diamond on wide field optics
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizuno, Kosuke

× Mizuno, Kosuke

WEKO 783420

Mizuno, Kosuke

Search repository
Ishiwata, Hitoshi

× Ishiwata, Hitoshi

WEKO 783421

Ishiwata, Hitoshi

Search repository
Masuyama, Yuta

× Masuyama, Yuta

WEKO 783422

Masuyama, Yuta

Search repository
Iwasaki, Takayuki

× Iwasaki, Takayuki

WEKO 783423

Iwasaki, Takayuki

Search repository
Hatano, Mutsuko

× Hatano, Mutsuko

WEKO 783424

Hatano, Mutsuko

Search repository
Masuyama, Yuta

× Masuyama, Yuta

WEKO 783425

en Masuyama, Yuta

Search repository
Hatano, Mutsuko

× Hatano, Mutsuko

WEKO 783426

en Hatano, Mutsuko

Search repository
抄録
内容記述タイプ Abstract
内容記述 Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing.
Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal.

This work was supported by MEXT Q-LEAP, CAO PRISM, Japan.
[1] Mizuno et al., AIP advances 2018
[2][3] Boss, Schmitt
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Gordon Research Conference "Quantum Sensing Applications in Metrology and Imaging"
発表年月日
日付 2019-06-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:44:51.698232
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3