  1. 原著論文

Development of a Simplified Radiation-Induced Emulsion Graft Polymerization Method and Its Application to the Fabrication of a Heavy Metal Adsorbent

https://repo.qst.go.jp/records/76585
https://repo.qst.go.jp/records/76585
adb0fa16-1f59-498d-acea-b0c4c14c1b05
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-08-28
タイトル
タイトル Development of a Simplified Radiation-Induced Emulsion Graft Polymerization Method and Its Application to the Fabrication of a Heavy Metal Adsorbent
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Omichi, Masaaki

× Omichi, Masaaki

WEKO 807322

Omichi, Masaaki

Search repository
Ueki, Yuuji

× Ueki, Yuuji

WEKO 807323

Ueki, Yuuji

Search repository
Seko, Noriaki

× Seko, Noriaki

WEKO 807324

Seko, Noriaki

Search repository
Maekawa, Yasunari

× Maekawa, Yasunari

WEKO 807325

Maekawa, Yasunari

Search repository
Omichi, Masaaki

× Omichi, Masaaki

WEKO 807326

en Omichi, Masaaki

Search repository
Ueki, Yuuji

× Ueki, Yuuji

WEKO 807327

en Ueki, Yuuji

Search repository
Seko, Noriaki

× Seko, Noriaki

WEKO 807328

en Seko, Noriaki

Search repository
Maekawa, Yasunari

× Maekawa, Yasunari

WEKO 807329

en Maekawa, Yasunari

Search repository
抄録
内容記述タイプ Abstract
内容記述 A simplified radiation-induced emulsion graft polymerization (SREG) method is proposed. This method involves a convenient and easy degassing process of a monomer solution using a commercially available sealed glass jar. A loaded weight on the lid of the jar was used to control the jar’s internal pressure as the degassing of the monomer solution took place using a vacuum pump. The degassing method was highly reproducible, resulting from no bumping of the monomer solution. The initial grafting velocity was proportional to the absorbed doses of pre-irradiation between 5 and 20 kGy. This result indicates that dissolved oxygen was sufficiently eliminated from the monomer solution at such a level where the remaining oxygen had little effect on the grafting reaction at a dose of 5 kGy. The method was then applied to the fabrication of a heavy metal adsorbent that possessed a sufficient adsorption capacity of Co(II) ions. The SREG method is applicable to the fabrication of a wide variety of functional graft polymers because high-dose-rate gamma-ray radiation and expensive experimental equipment are not necessary.
書誌情報 Polymers

巻 11, 号 8, p. 1373-1-1373-11, 発行日 2019-08
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 2073-4360
DOI
識別子タイプ DOI
関連識別子 10.3390/polym11081373
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/2073-4360/11/8/1373
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:35:37.878585
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3