WEKO3
アイテム
Development of a Simplified Radiation-Induced Emulsion Graft Polymerization Method and Its Application to the Fabrication of a Heavy Metal Adsorbent
https://repo.qst.go.jp/records/76585
https://repo.qst.go.jp/records/76585adb0fa16-1f59-498d-acea-b0c4c14c1b05
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2019-08-28 | |||||
| タイトル | ||||||
| タイトル | Development of a Simplified Radiation-Induced Emulsion Graft Polymerization Method and Its Application to the Fabrication of a Heavy Metal Adsorbent | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Omichi, Masaaki
× Omichi, Masaaki× Ueki, Yuuji× Seko, Noriaki× Maekawa, Yasunari× Omichi, Masaaki× Ueki, Yuuji× Seko, Noriaki× Maekawa, Yasunari |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | A simplified radiation-induced emulsion graft polymerization (SREG) method is proposed. This method involves a convenient and easy degassing process of a monomer solution using a commercially available sealed glass jar. A loaded weight on the lid of the jar was used to control the jar’s internal pressure as the degassing of the monomer solution took place using a vacuum pump. The degassing method was highly reproducible, resulting from no bumping of the monomer solution. The initial grafting velocity was proportional to the absorbed doses of pre-irradiation between 5 and 20 kGy. This result indicates that dissolved oxygen was sufficiently eliminated from the monomer solution at such a level where the remaining oxygen had little effect on the grafting reaction at a dose of 5 kGy. The method was then applied to the fabrication of a heavy metal adsorbent that possessed a sufficient adsorption capacity of Co(II) ions. The SREG method is applicable to the fabrication of a wide variety of functional graft polymers because high-dose-rate gamma-ray radiation and expensive experimental equipment are not necessary. | |||||
| 書誌情報 |
Polymers 巻 11, 号 8, p. 1373-1-1373-11, 発行日 2019-08 |
|||||
| 出版者 | ||||||
| 出版者 | MDPI | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 2073-4360 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.3390/polym11081373 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://www.mdpi.com/2073-4360/11/8/1373 | |||||