ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Collisionless electrostatic shock acceleration of proton using high intensity laser

https://repo.qst.go.jp/records/76496
https://repo.qst.go.jp/records/76496
8f3b7ddc-382e-4083-b0d5-2e33e6b6b6c8
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-07-23
タイトル
タイトル Collisionless electrostatic shock acceleration of proton using high intensity laser
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ota, Masato

× Ota, Masato

WEKO 876489

Ota, Masato

Search repository
Morace, Allesio

× Morace, Allesio

WEKO 876490

Morace, Allesio

Search repository
Kumar, Rajesh

× Kumar, Rajesh

WEKO 876491

Kumar, Rajesh

Search repository
Kambayashi, S.

× Kambayashi, S.

WEKO 876492

Kambayashi, S.

Search repository
Egashira, Syunsuke

× Egashira, Syunsuke

WEKO 876493

Egashira, Syunsuke

Search repository
Kanasaki, Masato

× Kanasaki, Masato

WEKO 876494

Kanasaki, Masato

Search repository
Fukuda, Yuji

× Fukuda, Yuji

WEKO 876495

Fukuda, Yuji

Search repository
Sakawa, Youichi

× Sakawa, Youichi

WEKO 876496

Sakawa, Youichi

Search repository
Fukuda, Yuuji

× Fukuda, Yuuji

WEKO 876497

en Fukuda, Yuuji

Search repository
抄録
内容記述タイプ Abstract
内容記述 An experiment on ion acceleration in near-critical density plasma is conducted using a high-intensity 1053 nm linearly polarized laser pulse with a laser intensity of 3.5 × 10^18 W/cm^2. In this experiment a thin 0.7 μm thick CH foil is irradiated with a low-intensity, nanosecond pulse to create a near-critical density plasma. Then the high-intensity pulse is focused on the target at di erent time delays in order to verify what density pro le is optimal for collisionless shock generation. Ion acceleration and electron spectra are observed by Radio Chromic Film and magnetic electron spectrometer. Proton dominant acceleration is con rmed at some time delays by CR-39. It is suggested that the accelerated ions are produced by Collisionless Electrostatic Shock comparing the experimental results with numerical/computational results.
書誌情報 High Energy Density Physics

巻 33, p. 100697-1-100697-4, 発行日 2019-07
出版者
出版者 Elsevier B.V.
ISSN
収録物識別子タイプ ISSN
収録物識別子 1574-1818
DOI
識別子タイプ DOI
関連識別子 10.1016/j.hedp.2019.100697
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.hedp.2019.100697
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:05:12.991989
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3