WEKO3
アイテム
Radiation Chemical Yield of Hydroxyl Radicals for Accelerator-based Boron Neutron Capture Therapy: Dose Assessment of B-10(n,alpha)Li-7 Reaction Using Coumarin-3-Carboxilic Solution
https://repo.qst.go.jp/records/76412
https://repo.qst.go.jp/records/7641219d82c3f-0e16-4fd8-bcb7-e0fde6ff060f
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-08-05 | |||||
タイトル | ||||||
タイトル | Radiation Chemical Yield of Hydroxyl Radicals for Accelerator-based Boron Neutron Capture Therapy: Dose Assessment of B-10(n,alpha)Li-7 Reaction Using Coumarin-3-Carboxilic Solution | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kusumoto, Tamon
× Kusumoto, Tamon× Ogawara, Ryo× Kusumoto, Tamon× Ogawara, Ryo |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Evaluation of the characteristics of accelerator-based thermal neutron fields is recognized as an important issue when discussing the effectiveness of boron neutron capture therapy (BNCT). In this study, we propose that the radiation chemical yield (G value) of hydroxyl radicals (Goh•) can be considered a universal parameter for the description of the accelerator-based thermal neutron field. The Goh• of the 10B(n,α)7Li reaction was quantitatively evaluated using an aqueous coumarin-3-carboxylic acid (3CCA) solution, and was discriminated from that of contaminations (i.e., γ rays and fast neutrons). The Goh• of the 10B(n,α)7Li reaction was 0.107 ± 0.004 OH•/100 eV, which is almost equivalent to that exposed to α particles with an energy of 6.0 MeV. Since the Goh• of γ rays from a 60Co source is 2.03 ± 0.05 OH•/100 eV, this lower value suggests that indirect action by the 10B(n,α)7Li reaction is not dominant in BNCT. However, our results indicate that one can assess the 60Co equivalent dose of the 10B(n,α)7Li reaction in water from the Goh• derived using aqueous 3CCA solution in the accelerator-based thermal neutron field. | |||||
書誌情報 |
RADIATION RESEARCH 巻 191, 号 5, p. 460-465, 発行日 2019-08 |
|||||
出版者 | ||||||
出版者 | Radiation Research Society | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0033-7587 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1667/RR15318.1 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.rrjournal.org/doi/pdf/10.1667/RR15318.1 |