Measurements of thermal-neutron capture cross-section and resonance integral of neptunium-237

https://repo.qst.go.jp/records/76399
https://repo.qst.go.jp/records/76399
39479dea-2304-49f1-b3b2-5f2ade66ebbf
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-08-01
タイトル
タイトル Measurements of thermal-neutron capture cross-section and resonance integral of neptunium-237
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakamura, Shoji

× Nakamura, Shoji

WEKO 800978

Nakamura, Shoji

Search repository
Kitatani, Fumito

× Kitatani, Fumito

WEKO 800979

Kitatani, Fumito

Search repository
Kimura, Atsushi

× Kimura, Atsushi

WEKO 800980

Kimura, Atsushi

Search repository
Uehara, Akihiro

× Uehara, Akihiro

WEKO 800981

Uehara, Akihiro

Search repository
Fujii, Toshiyuki

× Fujii, Toshiyuki

WEKO 800982

Fujii, Toshiyuki

Search repository
Uehara, Akihiro

× Uehara, Akihiro

WEKO 800983

en Uehara, Akihiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 The thermal-neutron capture cross-section (σ0) and resonance integral (I0) were measured for the 237Np(n,γ) 238Np reaction by an activation method. A method with a Gadolinium filter, which is similar to the Cadmium difference method, was used to measure the σ0 with paying attention to the first resonance at 0.489 eV of 237Np, and a value of 0.133 eV was taken as a cut-off energy. Neptunium-237 samples were irradiated at the pneumatic tube of the Kyoto University Research Reactor in Institute for Integral Radiation and Nuclear Science, Kyoto University. Wires of Co/Al and Au/Al alloys were used as monitors to determine hermalneutron fluxes and epi-thermal Westcott’s indices at an irradiation position. A γ-ray spectroscopy was used to measure activities of 237Np, 238Np and neutron monitors. On the basis of Westcott’s convention, the σ0 and I0 values were derived as 186.9 ± 6.2 barn, and 1009 ± 90 barn, respectively.
書誌情報 JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY

巻 56, 号 6, p. 493-502, 発行日 2019-04
出版者
出版者 Taylor & Francis
ISSN
収録物識別子タイプ ISSN
収録物識別子 0022-3131
DOI
識別子タイプ DOI
関連識別子 10.1080/00223131.2019.1598304
関連サイト
識別子タイプ URI
関連識別子 https://www.tandfonline.com/doi/full/10.1080/00223131.2019.1598304
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:37:52.465398
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3