  1. 原著論文

COMPARATIVE STUDY ON PERFORMANCE OF VARIOUS ENVIRONMENTAL RADIATION MONITORS

https://repo.qst.go.jp/records/76210
https://repo.qst.go.jp/records/76210
6960be1d-9d03-45ce-b4b1-087bf7a3eff4
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-07-05
タイトル
タイトル COMPARATIVE STUDY ON PERFORMANCE OF VARIOUS ENVIRONMENTAL RADIATION MONITORS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tamakuma, Y.

× Tamakuma, Y.

WEKO 898615

Tamakuma, Y.

Search repository
Yamada, R.

× Yamada, R.

WEKO 898616

Yamada, R.

Search repository
Suzuki, T.

× Suzuki, T.

WEKO 898617

Suzuki, T.

Search repository
Kuroki, T.

× Kuroki, T.

WEKO 898618

Kuroki, T.

Search repository
Saga, R.

× Saga, R.

WEKO 898619

Saga, R.

Search repository
Mizuno, H.

× Mizuno, H.

WEKO 898620

Mizuno, H.

Search repository
Sasaki, H.

× Sasaki, H.

WEKO 898621

Sasaki, H.

Search repository
Iwaoka, K.

× Iwaoka, K.

WEKO 898622

Iwaoka, K.

Search repository
Hosoda, M.

× Hosoda, M.

WEKO 898623

Hosoda, M.

Search repository
Tokonami, S.

× Tokonami, S.

WEKO 898624

Tokonami, S.

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 898625

en Iwaoka, Kazuki

Search repository
抄録
内容記述タイプ Abstract
内容記述 After the Fukushima Daiichi Nuclear Power Plant accident, the radiation dose for first responders was not evaluated accurately due to lack of the monitoring data. It has been important to evaluate a radiation dose for workers in emergency response at a nuclear accident. In this study, a new device which can evaluate both of external and internal exposure doses was developed and the performance of various environmental radiation monitors including commercially available monitors were tested and compared from the viewpoint of an environmental monitoring at emergency situation. Background counts of the monitors and the ambient dose equivalent rate were measured in Fukushima Prefecture. The detection limit for beta particles was evaluated by the method of ISO11929. The sensitivity for gamma-rays of the dust monitor using a ZnS(Ag) and a plastic scintillator was high, but that of the external exposure monitor using a silicon photodiode with CsI(Tl) crystal was relatively low. The detection limit ranged 190–280 Bq m−3 at 100 μSv h−1, exceeding the detection limit of 100 Bq m−3 in the minimum requirement by the National Regulation Authority in Japan. Use of the shielding with lead is necessary to achieve the minimum requirement. These results indicate that the dust monitor using a ZnS(Ag) scintillator and a plastic scintillator is suitable for the external exposure monitor and the developed internal exposure monitor is for the internal exposure monitor at emergency situation among the evaluated monitors. In the future study, the counting efficiency, the relative uncertainty and the performance of the detection for alpha particles will be evaluated, and it will be considered which type of a monitor is suitable after taking the portability into account.
書誌情報 Radiation Protection Dosimetry

巻 184, 号 3-4, p. 307-310, 発行日 2019-07
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncz104
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1093/rpd/ncz104
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:58:19.273465
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3