ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

210Po as a source of natural radioactivity in cigarettes distributed in the Philippines

https://repo.qst.go.jp/records/76208
https://repo.qst.go.jp/records/76208
4fa13066-5d9c-43be-9d91-58f6f203db4d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-07-05
タイトル
タイトル 210Po as a source of natural radioactivity in cigarettes distributed in the Philippines
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 826577

Iwaoka, Kazuki

Search repository
B. Enriquez, Eliza

× B. Enriquez, Eliza

WEKO 826578

B. Enriquez, Eliza

Search repository
Yajima, Kazuaki

× Yajima, Kazuaki

WEKO 826579

Yajima, Kazuaki

Search repository
Hosoda, Masahiro

× Hosoda, Masahiro

WEKO 826580

Hosoda, Masahiro

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 826581

Tokonami, Shinji

Search repository
Yonehara, Hidenori

× Yonehara, Hidenori

WEKO 826582

Yonehara, Hidenori

Search repository
Y. Garcia, Teofilo

× Y. Garcia, Teofilo

WEKO 826583

Y. Garcia, Teofilo

Search repository
Kanda, Reiko

× Kanda, Reiko

WEKO 826584

Kanda, Reiko

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 826585

en Iwaoka, Kazuki

Search repository
Yajima, Kazuaki

× Yajima, Kazuaki

WEKO 826586

en Yajima, Kazuaki

Search repository
Kanda, Reiko

× Kanda, Reiko

WEKO 826587

en Kanda, Reiko

Search repository
抄録
内容記述タイプ Abstract
内容記述 The natural radioactive nuclides especially 210Po, are volatilized at the temperature (600 – 800 ºC) of a burning cigarette and are taken into the human body. Therefore, analysis of natural radioactivity of 210Po in cigarettes and the effective dose to smokers should be evaluated. The activity concentration of 210Po in sixteen brands of Philippine cigarettes was measured by alpha spectrometry, and estimation of effective dose of 210Po to smokers was performed. The activity concentration of 210Po in cigarettes distributed in the Philippines ranged from 5.5 to 17.8 mBq/cigarette and the mean value of their activity concentrations was 12.0 mBq/cigarette. The mean value of annual effective doses of 210Po to smokers obtained from these activity concentrations was 0.021 mSv/y, which was lower than the reference level (1-20 mSv/y) for existing situation in ICRP Publication 103.
書誌情報 Perspectives in Science

巻 12, p. 100400-1, 発行日 2019-07
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 2213-0209
DOI
識別子タイプ DOI
関連識別子 10.1016/j.pisc.2019.100400
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S2213020919300072
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:27:17.645675
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3