WEKO3
アイテム
Demonstration of 1 MV insulation for the vacuum insulated beam source in the ITER neutral beam system
https://repo.qst.go.jp/records/76205
https://repo.qst.go.jp/records/76205bd6f2cdb-9965-4486-ba7c-36e8173f964e
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-07-05 | |||||
タイトル | ||||||
タイトル | Demonstration of 1 MV insulation for the vacuum insulated beam source in the ITER neutral beam system | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
小島, 有志
× 小島, 有志× 戸張, 博之× 梅田, 尚孝× 柏木, 美恵子× 市川, 雅浩× 平塚, 淳一× Shibata, Naoki× Yamashita, Yasuo× Dairaku, Masayuki× Yamanaka, Haruhiko× Watanabe, Kazuhiro× Y.YAMANO(Saitama, University)× L.R.Grisham(Princeton, Plasma Physics Laboratory)× Kojima, Atsushi× Tobari, Hiroyuki× Umeda, Naotaka× Kashiwagi, Mieko× Ichikawa, Masahiro× Hiratsuka, Junichi× Shibata, Naoki× Yamashita, Yasuo× Dairaku, Masayuki× Yamanaka, Haruhiko× Watanabe, Kazuhiro |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | For the realization of the ITER neutral beam (NB) system, a method for achieving the acceleration voltage of 1 MV for the vacuum insulated beam source (VIBS) has been developed. Additionally, the design basis for the 1 MV vacuum insulation has also been developed by integrating previous empirical scaling of the voltage holding capability for plane and coaxial electrodes with new scaling for the corner region where the locally-concentrated electric field is generated. The scaling clarified that a product of electric field and voltage obtained by electric field analysis in the beam source vessel was much higher than the allowable level. Therefore, in order to improve the voltage holding capability, electrostatic shields having intermediate potential have been proposed. Consequently, it was found that the VIBS needs to be surrounded by more than three intermediate shields instead of a single gap insulation of 1 MV. Reliability of the design basis of the developed intermediated shields has been experimentally verified by improving the 1.3 m single gap insulation in the voltage holding test. As a result, the sustainable voltage has been significantly improved from 0.7 MV with the single gap to 1 MV with shielding up to the power supply limit. This result ensures the realization of the 1 MV VIBS in the ITER NB system. | |||||
書誌情報 |
Nuclear Fusion 巻 59, 号 8, p. 086042-1~7, 発行日 2019-07 |
|||||
出版者 | ||||||
出版者 | IOP SCIENCE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0029-5515 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/1741-4326/ab1ab0 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://iopscience.iop.org/article/10.1088/1741-4326/ab1ab0 |