ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Study of Chemical Etching Conditions for Alpha-particle Detection and Visualization Using Solid State Nuclear Track Detectors

https://repo.qst.go.jp/records/76203
https://repo.qst.go.jp/records/76203
529ab877-3192-4817-a8b5-90399ea4f458
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-07-05
タイトル
タイトル Study of Chemical Etching Conditions for Alpha-particle Detection and Visualization Using Solid State Nuclear Track Detectors
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamada, Ryohei

× Yamada, Ryohei

WEKO 914618

Yamada, Ryohei

Search repository
Odagiri, Taiki

× Odagiri, Taiki

WEKO 914619

Odagiri, Taiki

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 914620

Iwaoka, Kazuki

Search repository
Hosoda, Masahiro

× Hosoda, Masahiro

WEKO 914621

Hosoda, Masahiro

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 914622

Tokonami, Shinji

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 914623

en Iwaoka, Kazuki

Search repository
抄録
内容記述タイプ Abstract
内容記述 We evaluate radon/thoron and its progeny concentration using passive-type monitors using CR-39 plates. After exposure, it is necessary to do chemical etching for CR-39 plates. In the present study, we considered shortening of chemical etching time for CR-39 and enlargement of the track diameter (i.e. etch pit diameter) aiming for introduction of automatic counting system in the future. Optimum conditions were determined by changing solution concentration, solution temperature and etching time. As a result, the optimized conditions (concentration, temperature and etching time) were determined to be 8 M NaOH solution, 75°C and 10 hours. This result of etching time showed that the chemical etching was completed in less than half of conventional etching time. Furthermore, it was suggested that shorter etching time would be possible if we do not consider the enlargement of conventional track diameter.
書誌情報 Radiation Environment and Medicine

巻 8, 号 1, p. 21-25, 発行日 2019-07
出版者
出版者 弘前大学出版会
ISSN
収録物識別子タイプ ISSN
収録物識別子 2423-9097
関連サイト
識別子タイプ URI
関連識別子 http://crss.hirosaki-u.ac.jp/rem_archive/radiation-environment-and-medicine-vol-8-no-1
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:52:47.267508
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3