ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Initial evaluation of novel shape radioactive sample sources with 22Na and 68Ge

https://repo.qst.go.jp/records/76159
https://repo.qst.go.jp/records/76159
07afb2c8-9ade-46c5-964a-9be157b35fe1
Item type 会議発表用資料 / Presentation(1)
公開日 2019-04-15
タイトル
タイトル Initial evaluation of novel shape radioactive sample sources with 22Na and 68Ge
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 赤松, 剛

× 赤松, 剛

WEKO 765639

赤松, 剛

Search repository
吉田, 英治

× 吉田, 英治

WEKO 765640

吉田, 英治

Search repository
前田, 貴雅

× 前田, 貴雅

WEKO 765641

前田, 貴雅

Search repository
脇坂, 秀克

× 脇坂, 秀克

WEKO 765642

脇坂, 秀克

Search repository
田島, 英朗

× 田島, 英朗

WEKO 765643

田島, 英朗

Search repository
三家本, 隆弘

× 三家本, 隆弘

WEKO 765644

三家本, 隆弘

Search repository
山谷, 泰賀

× 山谷, 泰賀

WEKO 765645

山谷, 泰賀

Search repository
Akamatsu, Go

× Akamatsu, Go

WEKO 765646

en Akamatsu, Go

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 765647

en Yoshida, Eiji

Search repository
Maeda, Takamasa

× Maeda, Takamasa

WEKO 765648

en Maeda, Takamasa

Search repository
Wakizaka, Hidekatsu

× Wakizaka, Hidekatsu

WEKO 765649

en Wakizaka, Hidekatsu

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 765650

en Tashima, Hideaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 765651

en Yamaya, Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 【Purpose】Recent progress in radioactive source production technology made it possible to generate a sealed radioactive source with flexible shape. The Japan Radioisotope Association (JRIA) developed three types of novel shape sample sources [5-cm-diameter cylinder, 60-cm flexible tube, Derenzo-like multi-rod (rod diameter: 1.6~6.0 mm)] with 22Na and 68Ge. These novel sources can be applied for a PET scanner QA/QC, such as daily QC and performance measurements. In this work, we evaluated uniformity and long-term stability of these sample sources.

【Method】All sources were scanned by the Biograph mCT Flow every month for three months. For the 5-cm-diameter cylindrical source, we placed circular regions-of-interest (ROIs) on three axial slices and evaluated its uniformity by calculating a coefficient of variation (CV). In addition, the measured activity decay was evaluated to confirm these sources correctly follow a half-life of corresponding radionuclide. For the 60-cm tube source, the ROI was placed to cover the whole source and calculated its total activity. The Derenzo-like multi-rod source was scanned by not only Biograph mCT Flow but also Inveon small-animal PET scanner and brain-dedicated helmet-type PET scanner. We visually evaluated the uniformity of activity distributions of the Derenzo-like source.

【Result】The CV among axial slices for the cylindrical source was 2% or less. The measured activity decays of the cylindrical source and the tube source followed the half-life of corresponding radionuclide. We were able to compare image resolutions among the three scanners using the Derenzo-like source. The Inveon scanner visualized the smallest rod of which activity seemed to be uniformly distributed.

【Conclusion】The uniformity and stability of the three sample sources have been maintained for three months. We are to try to make more complicated shape sources for a PET scanner QA/QC.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第75回日本放射線技術学会総会学術大会
発表年月日
日付 2019-04-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:51:29.991459
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3