ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Measurement of the metal impurity in PET probe using the HPLC post-column method

https://repo.qst.go.jp/records/76118
https://repo.qst.go.jp/records/76118
f063bba2-dc4c-4215-aaad-2c0c3a59342f
Item type 会議発表用資料 / Presentation(1)
公開日 2019-06-03
タイトル
タイトル Measurement of the metal impurity in PET probe using the HPLC post-column method
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hanyu, Masayuki

× Hanyu, Masayuki

WEKO 764972

Hanyu, Masayuki

Search repository
Ishii, Hideki

× Ishii, Hideki

WEKO 764973

Ishii, Hideki

Search repository
Nengaki, Nobuki

× Nengaki, Nobuki

WEKO 764974

Nengaki, Nobuki

Search repository
Ogawa, Masanao

× Ogawa, Masanao

WEKO 764975

Ogawa, Masanao

Search repository
Arashi, Daisuke

× Arashi, Daisuke

WEKO 764976

Arashi, Daisuke

Search repository
Furutsuka, Kenji

× Furutsuka, Kenji

WEKO 764977

Furutsuka, Kenji

Search repository
Hashimoto, Hiroki

× Hashimoto, Hiroki

WEKO 764978

Hashimoto, Hiroki

Search repository
Kawamura, Kazunori

× Kawamura, Kazunori

WEKO 764979

Kawamura, Kazunori

Search repository
Ming-Rong, Zhang

× Ming-Rong, Zhang

WEKO 764980

Ming-Rong, Zhang

Search repository
Hanyu, Masayuki

× Hanyu, Masayuki

WEKO 764981

en Hanyu, Masayuki

Search repository
Ishii, Hideki

× Ishii, Hideki

WEKO 764982

en Ishii, Hideki

Search repository
Nengaki, Nobuki

× Nengaki, Nobuki

WEKO 764983

en Nengaki, Nobuki

Search repository
Ogawa, Masanao

× Ogawa, Masanao

WEKO 764984

en Ogawa, Masanao

Search repository
Arashi, Daisuke

× Arashi, Daisuke

WEKO 764985

en Arashi, Daisuke

Search repository
Furutsuka, Kenji

× Furutsuka, Kenji

WEKO 764986

en Furutsuka, Kenji

Search repository
Hashimoto, Hiroki

× Hashimoto, Hiroki

WEKO 764987

en Hashimoto, Hiroki

Search repository
Kawamura, Kazunori

× Kawamura, Kazunori

WEKO 764988

en Kawamura, Kazunori

Search repository
Ming-Rong, Zhang

× Ming-Rong, Zhang

WEKO 764989

en Ming-Rong, Zhang

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objectives
In the last few years new emerging metal-mediated radiolabeling methods have facilitated access to probes which had been so far inaccessible or difficult to produce using conventional labeling procedures. Particularly, procedures for copper-mediated 18F-fluorination discovered by Gouverneur et al. [1] and further developed by inventors and others [2]. On the other hands, a guideline called ICH-Q3D regulates the permission limit of elemental impurities in conventional drugs. Hence, we should consider and prepare to reflect such regulation into daily radio-pharmaceutical productions. The most common detection technique for metal (elements) impurity is inductively coupled plasma mass spectrometry (ICP-MS) detection. Although ICP-MS is a suitable instrument to analyze trace amount of metallic impurities with high sensitivity, it is cumbersome for routine assessment. We report here the metal impurity in PET probe measured by using the HPLC post-column method.
Methods
Production of [18F]DOPA by copper-mediated method was performed using homemade automation single reactor module. The residual amount of copper in the final solution were analyzed using a metal-free JASCO Extrema HPLC system (Tokyo, Japan) including two pumps, auto sampler, column-oven, and a UV–VIS detector. One pump was used to deliver MetPac PDCA eluent through the analytical column, and the other one was used to deliver PAR diluent. The sample solution was separated through an IonPac CS5A analytic column (4.6 × 250mm), and the eluent mixed with the dye PAR was analyzed by the UV–VIS detector at 520 nm of copper. Flow rates for MetPac PDCA eluent and PAR diluent solution were 1.2 mL/min and 0.6 mL/min, respectively. Calibration curves for copper ranging from 10 to 2000 μg/L were made from the TraceCERT® ICP-MS standard at an injection volume of 50 μL.
Results
The concentration of copper was measured with a good linearity in the range of 10 to 2000 μg/mL (R2>0.98), repeatability on three injections at the same day in less than 5% relative standard deviation (% RSD). We enabled detecting the residual amount of copper in [18F]DOPA using the HPLC post-column system, and calculate the residual amount of copper in [18F]DOPA (0.03 ppm±0.01ppm). This is significantly below any level of concern according to the ICH Guideline of Elemental Impurities (Q3D). We will report the residual amount of copper in [11C]product using copper-mediated cyanation.
Conclusions
The post-column evaluation provided considerable sensitivity for metal impurity within a short time (10 min), suggesting that this method is suitable for daily QC because of the simplicity and prompt measurement. Therefore, we used the data obtained by the post-column method only for estimating metal impurity of PET probe in a daily QC protocol.
Acknowledgements
This work was supported by JSPS KAKENHI Grant Number 18K07281.
Reference
[1] Tredwell, M., et al., Angew. Chem. 2014, 126, 1-6.
[2] Zarrad, F., et al., Molecules 2017, 22, 2231; doi:10.3390/molecules22122231.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 ISRS2019
発表年月日
日付 2019-06-30
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:51:46.463006
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3