ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Derivation and Validity Evaluation of Calibration Factors for Activated-charcoal Radon Collectors

https://repo.qst.go.jp/records/75831
https://repo.qst.go.jp/records/75831
2ec18dc5-72ef-4d5c-93d4-29a1def9677f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-05-17
タイトル
タイトル Derivation and Validity Evaluation of Calibration Factors for Activated-charcoal Radon Collectors
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Wakabayashi, Akiko

× Wakabayashi, Akiko

WEKO 899604

Wakabayashi, Akiko

Search repository
Yasuoka, Yumi

× Yasuoka, Yumi

WEKO 899605

Yasuoka, Yumi

Search repository
Janik, Miroslaw

× Janik, Miroslaw

WEKO 899606

Janik, Miroslaw

Search repository
Nagahama, Hiroyuki

× Nagahama, Hiroyuki

WEKO 899607

Nagahama, Hiroyuki

Search repository
Fukuhori, Nobutoshi

× Fukuhori, Nobutoshi

WEKO 899608

Fukuhori, Nobutoshi

Search repository
Mori, Yasunori

× Mori, Yasunori

WEKO 899609

Mori, Yasunori

Search repository
Arai, Yuria

× Arai, Yuria

WEKO 899610

Arai, Yuria

Search repository
Fujii, Satomi

× Fujii, Satomi

WEKO 899611

Fujii, Satomi

Search repository
Mukai, Takahiro

× Mukai, Takahiro

WEKO 899612

Mukai, Takahiro

Search repository
Janik, Miroslaw

× Janik, Miroslaw

WEKO 899613

en Janik, Miroslaw

Search repository
抄録
内容記述タイプ Abstract
内容記述 Radon collectors (e.g., PicoRad collectors) based on activated-charcoal have been used for screening and measuring radon. However, researchers at the U. S. Environmental Protection Agency reported that they could not verify the proper functioning of some commercially available radon detectors, including PicoRad collectors. In this study, we exposed two lots (with different expiration dates) of PicoRad collectors to the reference conditions at a controlled radon concentration within a radon chamber because the calibration factors were derived for use by a semi-empirical equation. Further, we exposed the PicoRad collectors to an uncontrolled radon atmosphere for conducting validity evaluation. The radon concentration results obtained by the Pico-Rad collectors using the semi-empirical equation were observed to be in good agreement with the conventional true radon concentration value. It denoted the optimal value of a quantity determined using a reference instrument. These experiments revealed that different values were required for the factors of the conversion equation of each radon collector lot with a different expiration date.
書誌情報 RADIOISOTOPES

巻 68, p. 317-329, 発行日 2019-05
出版者
出版者 Japan Radioisotope Association
ISSN
収録物識別子タイプ ISSN
収録物識別子 0033-8303
DOI
識別子タイプ DOI
関連識別子 10.3769/radioisotopes.68.317
関連サイト
識別子タイプ URI
関連識別子 https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncz100/5490187
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:57:58.953623
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3