EVALUATION OF A RADON AIR MONITOR IN THE MEASUREMENT OF RADON CONCENTRATION IN WATER IN COMPARISON WITH A LIQUID SCINTILLATION COUNTER

https://repo.qst.go.jp/records/75754
https://repo.qst.go.jp/records/75754
f3a8c38c-d067-4b78-a000-eeee7ebba4c3
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-05-07
タイトル
タイトル EVALUATION OF A RADON AIR MONITOR IN THE MEASUREMENT OF RADON CONCENTRATION IN WATER IN COMPARISON WITH A LIQUID SCINTILLATION COUNTER
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Higuchi , Shoko

× Higuchi , Shoko

WEKO 899570

Higuchi , Shoko

Search repository
Kamishiro , Yuuki

× Kamishiro , Yuuki

WEKO 899571

Kamishiro , Yuuki

Search repository
Ishihara , Maki

× Ishihara , Maki

WEKO 899572

Ishihara , Maki

Search repository
Yasuoka , Yumi

× Yasuoka , Yumi

WEKO 899573

Yasuoka , Yumi

Search repository
Mori , Yasunori

× Mori , Yasunori

WEKO 899574

Mori , Yasunori

Search repository
Hosoda , Masahiro

× Hosoda , Masahiro

WEKO 899575

Hosoda , Masahiro

Search repository
Iwaoka , Kazuki

× Iwaoka , Kazuki

WEKO 899576

Iwaoka , Kazuki

Search repository
Tokonami , Shinji

× Tokonami , Shinji

WEKO 899577

Tokonami , Shinji

Search repository
Takahashi , Rikiya

× Takahashi , Rikiya

WEKO 899578

Takahashi , Rikiya

Search repository
ミロソラフ, ヤニック

× ミロソラフ, ヤニック

WEKO 899579

ミロソラフ, ヤニック

Search repository
Muto , Jun

× Muto , Jun

WEKO 899580

Muto , Jun

Search repository
Nagahama , Hiroyuki

× Nagahama , Hiroyuki

WEKO 899581

Nagahama , Hiroyuki

Search repository
Mukai, Takahiro

× Mukai, Takahiro

WEKO 899582

Mukai, Takahiro

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 899583

en Iwaoka, Kazuki

Search repository
Janik, Miroslaw

× Janik, Miroslaw

WEKO 899584

en Janik, Miroslaw

Search repository
抄録
内容記述タイプ Abstract
内容記述 The World Health Organisation (WHO) recommends that the concentration of radon in water should be no more than 100 kBq m−3 (100 BqL−1) and the Codex Alimentarius Commission states that the limit of quantification (LOQ) of a method should be no more than one-fifth of this value. In this study, a degassing method with an RAD7 device was used to measure radon concentrations in water, compared to a liquid scintillation counter (LSC) method used as the reference, to investigate whether the numerical value of the LOQ of this method was more than 1/5 (20 kBq m–3) of 100 kBq m–3. The degassing method with leak prevention was shown to reach a target value of 20 kBq m−3 or less under a relative humidity of 6% or lower in the chamber of the RAD7 device. Accordingly, the RAD7 degassing method with leak prevention can be used to accurately measure radon concentrations in water within the guidance level set out by the WHO.
書誌情報 Radiation Protection Dosimetry

巻 184, 号 3-4, p. 426-429, 発行日 2019-05
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncz070
関連サイト
識別子タイプ URI
関連識別子 https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncz070/5481921
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:58:00.299327
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3