ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Optimizing intensity modulated particle therapy via rational combination of physical and biological approaches (17J420-FY2018)

https://repo.qst.go.jp/records/75684
https://repo.qst.go.jp/records/75684
69593c0b-3aee-4dce-8bd3-13a1d117195d
Item type 会議発表用資料 / Presentation(1)
公開日 2019-04-18
タイトル
タイトル Optimizing intensity modulated particle therapy via rational combination of physical and biological approaches (17J420-FY2018)
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sawakuchi, Gabriel

× Sawakuchi, Gabriel

WEKO 1071117

Sawakuchi, Gabriel

Search repository
McFadden, Conor

× McFadden, Conor

WEKO 1071118

McFadden, Conor

Search repository
Flint, David

× Flint, David

WEKO 1071119

Flint, David

Search repository
Bright, Scott

× Bright, Scott

WEKO 1071120

Bright, Scott

Search repository
Chakraborty, S.

× Chakraborty, S.

WEKO 1071121

Chakraborty, S.

Search repository
Grosshans, D.R.

× Grosshans, D.R.

WEKO 1071122

Grosshans, D.R.

Search repository
Mohan, R.

× Mohan, R.

WEKO 1071123

Mohan, R.

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 1071124

Furusawa, Yoshiya

Search repository
Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 1071125

Kodaira, Satoshi

Search repository
Konishi, Teruaki

× Konishi, Teruaki

WEKO 1071126

Konishi, Teruaki

Search repository
Satoshi, Kodaira

× Satoshi, Kodaira

WEKO 1071127

en Satoshi, Kodaira

Search repository
Teruaki, Konishi

× Teruaki, Konishi

WEKO 1071128

en Teruaki, Konishi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The goal of this project is to evaluate the role of deficiencies in DNA repair pathways on particle therapy (PT) response. We have exposed five cell lines (M059J, M059K, H1299, H460 and BxPC-3) to 6 MV x-rays, protons (100 MeV: 1.1, 2.5 and 7.8 keV/µm), He-ions (150 MeV/u: 2.2, 6.9 and 13.4 keV/µm) and C-ions (290 MeV/u: 13.5, 28.1 and 61.4 keV/µm) for clonogenic cell survival assessment. The response of the cell lines were then characterized in terms of the relative biological effectiveness (RBE). Here we presented updated values of the RBE of these cell lines, which ranged from 0.90-1.70 for protons, 0.87-1.30 for He-ions, and 1.11-1.97 for C-ions. Our data on RBE indicated that different cell lines respond widely differently to PT beams. We further demonstrated that DNA repair deficiencies play a major role in the response of cell lines to PT beams. Particularly, our data suggest that non-homologous end joining repair has a major role in repairing radiation induced DNA lesions.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 平成30年度放射線医学総合研究所 重粒子線がん治療装置等共同利用研究報告書
発表年月日
日付 2019-04-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:43:25.678164
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3