Commissioning of a fluoroscopic-based real-time markerless tumor tracking system in a superconducting rotating gantry for carbon-ion pencil beam scanning treatment

https://repo.qst.go.jp/records/75673
https://repo.qst.go.jp/records/75673
61432b40-f80b-4fd7-bf1a-f5805eae5400
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-01-22
タイトル
タイトル Commissioning of a fluoroscopic-based real-time markerless tumor tracking system in a superconducting rotating gantry for carbon-ion pencil beam scanning treatment
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 森, 慎一郎

× 森, 慎一郎

WEKO 798955

森, 慎一郎

Search repository
坂田, 幸辰

× 坂田, 幸辰

WEKO 798956

坂田, 幸辰

Search repository
平井, 隆介

× 平井, 隆介

WEKO 798957

平井, 隆介

Search repository
古市, 渉

× 古市, 渉

WEKO 798958

古市, 渉

Search repository
Shimabukuro, Kazuki

× Shimabukuro, Kazuki

WEKO 798959

Shimabukuro, Kazuki

Search repository
河野, 良介

× 河野, 良介

WEKO 798960

河野, 良介

Search repository
Woong Seop, Keum

× Woong Seop, Keum

WEKO 798961

Woong Seop, Keum

Search repository
井関, 康

× 井関, 康

WEKO 798962

井関, 康

Search repository
Kasai, Shigeru

× Kasai, Shigeru

WEKO 798963

Kasai, Shigeru

Search repository
Okaya, Keiko

× Okaya, Keiko

WEKO 798964

Okaya, Keiko

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 798965

en Mori, Shinichiro

Search repository
Sakata, Yukinobu

× Sakata, Yukinobu

WEKO 798966

en Sakata, Yukinobu

Search repository
Hirai, Ryusuke

× Hirai, Ryusuke

WEKO 798967

en Hirai, Ryusuke

Search repository
Furuichi, Wataru

× Furuichi, Wataru

WEKO 798968

en Furuichi, Wataru

Search repository
Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 798969

en Kohno, Ryosuke

Search repository
Keum, WoongSeop

× Keum, WoongSeop

WEKO 798970

en Keum, WoongSeop

Search repository
Iseki, Yasushi

× Iseki, Yasushi

WEKO 798971

en Iseki, Yasushi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To perform the final quality assurance of our fluoroscopic-based markerless tumor tracking for gated carbon-ion pencil beam scanning (C-PBS) radiotherapy using a rotating gantry system, we evaluated the geometrical accuracy and tumor tracking accuracy using a moving chest phantom with simulated respiration.
Methods: The positions of the dynamic flat panel detector (DFPD) and X-ray tube are subject to changes due to gantry sag. To compensate for this, we generated a geometrical calibration table (gantry flex map) in 15° gantry angle steps by the bundle adjustment method. We evaluated five metrics: (i) Geometrical calibration was evaluated by calculating chest phantom positional error using 2D/3D registration software for each 5° step of the gantry angle. (ii) Moving phantom displacement accuracy was measured (± 10 mm in 1-mm steps) with a laser sensor. (iii) Tracking accuracy was evaluated with machine learning (ML) and multi-template matching (MTM) algorithms, which used fluoroscopic images and digitally reconstructed radiographic (DRR) images as training data. The chest phantom was continuously moved ± 10 mm in a sinusoidal path with a moving cycle of 4 s and respiration was simulated with ± 5 mm expansion/contraction with a cycle of 2 s. This was performed with the gantry angle set at 0°, 45°, 120°, and 240°. (iv) Four types of interlock function were evaluated: tumor velocity, DFPD image brightness variation, tracking anomaly detection, and tracking positional inconsistency in between the two corresponding rays. (v) Gate on/off latency, gating control system latency, and beam irradiation latency were measured using a laser sensor and an oscilloscope.
Results: By applying the gantry flex map, phantom positional accuracy was improved from 1.03 mm/0.33° to < 0.45 mm/0.27° for all gantry angles. The moving phantom displacement error was 0.1 mm. Due to long computation time, the tracking accuracy achieved with ML was < 0.49 mm (= 95% confidence interval [CI]) for imaging rates of 15 fps and 7.5 fps; those at 30 fps were decreased to 1.84 mm (95% CI: 1.79 mm–1.92 mm). The tracking positional accuracy with MTM was < 0.52 mm (= 95% CI) for all gantry angles and imaging frame rates. The tumor velocity interlock signal delay time was 44.7 ms (= 1.3 frame). DFPD image brightness interlock latency was 34 ms (= 1.0 frame). The tracking positional error was improved from 2.27 ± 2.67 mm to 0.25 ± 0.24 mm by the tracking anomaly detection interlock function. Tracking positional inconsistency interlock signal was output within 5.0 ms. The gate on/off latency was < 82.7 ± 7.6 ms. The gating control system latency was < 3.1 ± 1.0 ms. The beam irradiation latency was < 8.7 ± 1.2 ms.
Conclusions: Our markerless tracking system is now ready for clinical use. We hope to shorten the computation time needed by the ML algorithm at 30 fps in the future.
書誌情報 Medical Physics

巻 46, 号 4, p. 1561-1574, 発行日 2019-04
出版者
出版者 Wiley
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
DOI
識別子タイプ DOI
関連識別子 10.1002/mp.13403
関連サイト
識別子タイプ URI
関連識別子 https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/mp.13403
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:38:43.626199
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3