WEKO3
アイテム
Radiobiological Characterization of Canine Malignant Melanoma Cell Lines with Different Types of Ionizing Radiation and Efficacy Evaluation with Cytotoxic Agents.
https://repo.qst.go.jp/records/75485
https://repo.qst.go.jp/records/7548508c4ed37-1e23-48f0-ba31-b1c0fbde22a2
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-27 | |||||
タイトル | ||||||
タイトル | Radiobiological Characterization of Canine Malignant Melanoma Cell Lines with Different Types of Ionizing Radiation and Efficacy Evaluation with Cytotoxic Agents. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
吉川, 陽人
× 吉川, 陽人× 砂田, 成章× 平川, 博一× 藤森, 亮× Elmegerhi, Suad× Leary, Del× 加藤, 宝光× Yoshikawa, Hiroto× Sunada, Shigeaki× Hirakawa, Hirokazu× Fujimori, Akira× Kato, Takamitsu |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Canine malignant melanoma (CMM) is a locally and systemically aggressive cancer that shares many biological and clinical characteristics with human mucosal melanoma. Hypofractionated radiation protocols have been used to treat CMM but little is known about its radiation biology. This pilot study is designed to investigate response of CMM cell lines to various ionizing radiations and cytotoxic agents to better understand this canine cancer. Four CMM cell lines were evaluated by clonogenic survival assay under aerobic and hypoxic conditions and parameters such as alpha beta (α/β) ratio, oxygen enhancement ratio (OER), and relative biological effectiveness (RBE) were calculated after Cs, 6 megavoltage (MV) photon, or carbon ion irradiation. Six cytotoxic agents (cisplatin, camptothecin, mitomycin C, bleomycin, methtyl methanesulfonate and etoposide) were also assessed for their efficacy. Under aerobic condition with 6 MV photon, the α/β ratio of the four cell lines ranged from 0.3 to >100, indicating a wide variation of cellular sensitivity. The ratio increased under hypoxic condition compared to aerobic condition and this was more dramatic in Cs and 6 MV photon treatments. OER of carbon was lower than Cs at D in 3 of the 4 cell lines. The RBE values generally increased with the increase of LET. Different cell lines showed sensitivity/resistance to different cytotoxic agents. This study revealed that CMM has a wide range of radiosensitivity and that hypoxia can reduce it, indicating that widely used hypofractionated protocols may not be optimal for all CMM patients. Several cytotoxic agents that have never been clinically assessed can improve treatment outcome. | |||||
書誌情報 |
International journal of molecular sciences 巻 20, 号 4, p. 841, 発行日 2019-02 |
|||||
出版者 | ||||||
出版者 | Basel | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1422-0067 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 30781345 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3390/ijms20040841 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6413050/ |