ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Development and optimization of water treatment reactors using TiO2-modified polymer beads with a refractive index identical to that of water

https://repo.qst.go.jp/records/74934
https://repo.qst.go.jp/records/74934
50fdf840-7c35-4168-b4a9-65860c08d012
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-03-25
タイトル
タイトル Development and optimization of water treatment reactors using TiO2-modified polymer beads with a refractive index identical to that of water
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Myoga, Arata

× Myoga, Arata

WEKO 1053846

Myoga, Arata

Search repository
Iwashita, Ryutaro

× Iwashita, Ryutaro

WEKO 1053847

Iwashita, Ryutaro

Search repository
Unno, Noriyuki

× Unno, Noriyuki

WEKO 1053848

Unno, Noriyuki

Search repository
Shin‑ichi, Satake

× Shin‑ichi, Satake

WEKO 1053849

Shin‑ichi, Satake

Search repository
Taniguchi, Jun

× Taniguchi, Jun

WEKO 1053850

Taniguchi, Jun

Search repository
Yuki, Kazuhisa

× Yuki, Kazuhisa

WEKO 1053851

Yuki, Kazuhisa

Search repository
関, 洋治

× 関, 洋治

WEKO 1053852

関, 洋治

Search repository
Yohji, Seki

× Yohji, Seki

WEKO 1053853

en Yohji, Seki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Various water purification reactors were constructed using beads of TiO2-coated MEXFLON, which is a fluoropolymer exhibiting a refractive index identical to that of water. The performance of these reactors was evaluated in a recirculation experiment utilizing an aqueous solution of methylene blue. Reactor pipes (length = 150 mm, internal diameter = 10 mm) were made of a fluorinated ethylene polymer with a refractive index of 1.338 and contained 206-bead clusters. A UV lamp was used to irradiate eight reactor pipes surrounding it. The above-mentioned eight bead-packed pipes were connected both in series and in parallel, and the performances of these two reactor types were compared. A pseudo-first-order rate constant of 0.70 h-1 was obtained for the series connection, whereas the corresponding value for the parallel connection was 1.5 times smaller, confirming the effectiveness of increasing the reaction surface by employing a larger number of beads.
書誌情報 Optical Review

巻 25, 号 3, p. 450-455, 発行日 2018-03
出版者
出版者 Springer
ISSN
収録物識別子タイプ ISSN
収録物識別子 1340-6000
DOI
識別子タイプ DOI
関連識別子 10.1007/s10043-018-0426-3
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:48:06.716459
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3