  1. 原著論文

System evaluation of automated production and inhalation of 15O-labeled gaseous radiopharmaceuticals for the rapid 15O-oxygen PET examinations

https://repo.qst.go.jp/records/74867
https://repo.qst.go.jp/records/74867
a7a535fb-8ed9-44b2-bf7f-b470dc36402f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-03-20
タイトル
タイトル System evaluation of automated production and inhalation of 15O-labeled gaseous radiopharmaceuticals for the rapid 15O-oxygen PET examinations
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Iguchi, Satoshi

× Iguchi, Satoshi

WEKO 790195

Iguchi, Satoshi

Search repository
Moriguchi, Tetsuaki

× Moriguchi, Tetsuaki

WEKO 790196

Moriguchi, Tetsuaki

Search repository
Yamazaki, Makoto

× Yamazaki, Makoto

WEKO 790197

Yamazaki, Makoto

Search repository
Hori, Yuki

× Hori, Yuki

WEKO 790198

Hori, Yuki

Search repository
Koshino, Kazuhiro

× Koshino, Kazuhiro

WEKO 790199

Koshino, Kazuhiro

Search repository
Toyoda, Kazunori

× Toyoda, Kazunori

WEKO 790200

Toyoda, Kazunori

Search repository
Teuho, Jarmo

× Teuho, Jarmo

WEKO 790201

Teuho, Jarmo

Search repository
Shimochi, Saeka

× Shimochi, Saeka

WEKO 790202

Shimochi, Saeka

Search repository
Terakawa, Yusuke

× Terakawa, Yusuke

WEKO 790203

Terakawa, Yusuke

Search repository
Fukuda, Tetsuya

× Fukuda, Tetsuya

WEKO 790204

Fukuda, Tetsuya

Search repository
C Takahashi, Jun

× C Takahashi, Jun

WEKO 790205

C Takahashi, Jun

Search repository
Nakagawara, Jyoji

× Nakagawara, Jyoji

WEKO 790206

Nakagawara, Jyoji

Search repository
Kanaya, Shigehiko

× Kanaya, Shigehiko

WEKO 790207

Kanaya, Shigehiko

Search repository
Iida, Hidehiro

× Iida, Hidehiro

WEKO 790208

Iida, Hidehiro

Search repository
Iguchi, Satoshi

× Iguchi, Satoshi

WEKO 790209

en Iguchi, Satoshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 BACKGROUND:15O-oxygen inhalation PET is unique in its ability to provide fundamental information regarding cerebral hemodynamics and energy metabolism in man. However, the use of 15O-oxygen has been limited in a clinical environment largely attributed to logistical complexity, in relation to a long study period, and the need to produce and inhale three sets of radiopharmaceuticals. Despite the recent works that enabled shortening of the PET examination period, radiopharmaceutical production has still been a limiting factor. This study was aimed to evaluate a recently developed radiosynthesis/inhalation system that automatically supplies a series of 15O-labeled gaseous radiopharmaceuticals of C15O, 15O2, and C15O2 at short intervals.
METHODS:The system consists of a radiosynthesizer which produces C15O, 15O2, and C15O2; an inhalation controller; and an inhalation/scavenging unit. All three parts are controlled by a common sequencer, enabling automated production and inhalation at intervals less than 4.5 min. The gas inhalation/scavenging unit controls to sequentially supply of qualified radiopharmaceuticals at given radioactivity for given periods at given intervals. The unit also scavenges effectively the non-inhaled radioactive gases. Performance and reproducibility are evaluated.
RESULTS:Using an 15O-dedicated cyclotron with deuteron of 3.5 MeV at 40 μA, C15O, 15O2, and C15O2 were sequentially produced at a constant rate of 1400, 2400, and 2000 MBq/min, respectively. Each of radiopharmaceuticals were stably inhaled at < 4.5 min intervals with negligible contamination from the previous supply. The two-hole two-layered face mask with scavenging device minimized the gaseous radioactivity surrounding subject's face, while maintaining the normocapnia during examination periods. Quantitative assessment of net administration doses could be assessed using a pair of radio-detectors at inlet and scavenging tubes, as 541 ± 149, 320 ± 103, 523 ± 137 MBq corresponding to 2-min supply of 2574 ± 255 MBq for C15O, and 1-min supply of 2220 ± 766 and 1763 ± 174 for 15O2 and C15O2, respectively.
CONCLUSIONS:The present system allowed for automated production and inhalation of series of 15O-labeled radiopharmaceuticals as required in the rapid 15O-Oxygen PET protocol. The production and inhalation were reproducible and improved logistical complexity, and thus the use of 15O-oxygen might have become practically applicable in clinical environments.
書誌情報 EJNMMI physics

巻 5, 号 1, p. 37, 発行日 2018-12
出版者
出版者 Springer
ISSN
収録物識別子タイプ ISSN
収録物識別子 2197-7364
PubMed番号
識別子タイプ PMID
関連識別子 30569426
DOI
識別子タイプ DOI
関連識別子 10.1186/s40658-018-0236-5
関連サイト
識別子タイプ URI
関連識別子 https://ejnmmiphys.springeropen.com/articles/10.1186/s40658-018-0236-5
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:42:11.485968
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3