WEKO3
アイテム
Improved neutron activation dosimetry for fusion
https://repo.qst.go.jp/records/74861
https://repo.qst.go.jp/records/74861bd1e9ae8-78ca-4ee0-a5fa-0b388ea92ff4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-19 | |||||
タイトル | ||||||
タイトル | Improved neutron activation dosimetry for fusion | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
T.Vasilopoulou
× T.Vasilopoulou× I.E.Stamatelatos× P.Batistoni× A.Colangeli× D.Flammini× N.Fonnesu× S.Loreti× B.Obryk× M.Pillon× R.Villari× Aiba, Nobuyuki× Uto, Hiroyasu× Imazawa, Ryota× Hoshino, Kazuo× Kamiya, Kensaku× Miyoshi, Yuuya× Asakura, Nobuyuki× Nakano, Tomohide× Ogawa, Toshihide× Suzuki, Takahiro× Tojo, Hiroshi× Urano, Hajime× Aiba, Nobuyuki× Uto, Hiroyasu× Imazawa, Ryota× Hoshino, Kazuo× Kamiya, Kensaku× Miyoshi, Yuuya× Asakura, Nobuyuki× Nakano, Tomohide× Ogawa, Toshihide× Suzuki, Takahiro× Tojo, Hiroshi× Urano, Hajime |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Neutron activation technique has been widely used for the monitoring of neutron fluence at the Joint European Torus (JET) whereas it is foreseen to be employed at future fusion plants, such as ITER and DEMO. Neutron activation provides a robust tool for the measurement of neutron fluence in the complex environment encountered in a tokamak. However, activation experiments previously performed at JET showed that the activation foils used need to be calibrated in a real fusion environment in order to provide accurate neutron fluence data. Triggered by this challenge, an improved neutron activation method for the evaluation of neutron fluence at fusion devices has been developed. Activation assemblies similar to those used at JET were irradiated under 14 MeV neutrons at the Frascati Neutron Generator (FNG) reference neutron field. The data obtained from the calibration experiment were applied for the analysis of activation foil measurements performed during the implemented JET Deuterium-Deuterium (D-D) campaign. The activation results were compared against thermoluminescence measurements and a satisfactory agreement was observed. The proposed method provides confidence on the use of activation technique for the precise estimation of neutron fluence at fusion devices and enables its successful implementation in the forthcoming JET Deuterium-Tritium (D–T) campaign. | |||||
書誌情報 |
Fusion Engineering and Design 巻 139, p. 109-114, 発行日 2019-02 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0920-3796 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.fusengdes.2019.01.002 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.fusengdes.2019.01.002 |