MCNP SIMULATIONS WITH A PERSONALISED VOXEL PHANTOM TO VERIFY 131I CONTENT IN THYROID ESTIMATED BASED ON MEASUREMENTS WITH AN NaI(Tl) SPECTROMETER

https://repo.qst.go.jp/records/73848
https://repo.qst.go.jp/records/73848
36369e39-b261-4466-958d-bbc0a6c561ad
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-02-27
タイトル
タイトル MCNP SIMULATIONS WITH A PERSONALISED VOXEL PHANTOM TO VERIFY 131I CONTENT IN THYROID ESTIMATED BASED ON MEASUREMENTS WITH AN NaI(Tl) SPECTROMETER
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 谷, 幸太郎

× 谷, 幸太郎

WEKO 861675

谷, 幸太郎

Search repository
國島, 直晃

× 國島, 直晃

WEKO 861676

國島, 直晃

Search repository
五十嵐, 悠

× 五十嵐, 悠

WEKO 861677

五十嵐, 悠

Search repository
金, ウンジュ

× 金, ウンジュ

WEKO 861678

金, ウンジュ

Search repository
飯本, 武志

× 飯本, 武志

WEKO 861679

飯本, 武志

Search repository
栗原, 治

× 栗原, 治

WEKO 861680

栗原, 治

Search repository
Tani, Kotaro

× Tani, Kotaro

WEKO 861681

en Tani, Kotaro

Search repository
Kunishima, Naoaki

× Kunishima, Naoaki

WEKO 861682

en Kunishima, Naoaki

Search repository
Igarashi, Yu

× Igarashi, Yu

WEKO 861683

en Igarashi, Yu

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 861684

en Eunjoo, Kim

Search repository
Iimoto, Takeshi

× Iimoto, Takeshi

WEKO 861685

en Iimoto, Takeshi

Search repository
Kurihara, Osamu

× Kurihara, Osamu

WEKO 861686

en Kurihara, Osamu

Search repository
抄録
内容記述タイプ Abstract
内容記述 One of the authors (O.K.) stayed in the area located ~110 km south from the Fukushima Daiichi Nuclear Power Plant during the arrival of radioactive plumes released into the environment due to the accident in March 2011 in Japan. A previous study determined his 131I thyroid content using an NaI(Tl) spectrometer. The one remaining issue was to investigate the measurement error due to inevitable differences in the configuration (e.g. the thyroid shape and volume) between the physical phantom employed for calibration of the spectrometer and the real subject. In the present study, Monte Carlo simulations for the thyroid measurements were performed using the Monte Carlo N-Particle (MNCP) code to investigate discrepancies in peak efficiencies of the spectrometer between the personalised voxel phantom created from O.K.’s magnetic resonance images and the several typical/reference phantoms that exist. As a result, the peak efficiencies for the Oak Ridge Institute of Nuclear Studies (ORINS) phantom were found to be comparable to those for the reference voxel phantoms reproducing realistic human anatomy (the Adult Male phantom and the Japanese Male phantom). The peak efficiency for the personalised phantom, on the other hand, was fairly close to that of the other physical phantom (the Transfer phantom) actually used for the calibration of the spectrometer, suggesting that the 131I thyroid content determined for him in the previous study was sufficiently accurate. The discrepancies of peak efficiencies at the primal photon energy of 131I (365 keV) among the different phantoms were improved by extending the distance between the neck and the spectrometer; however, the appropriate measurement geometry in an actual situation will depend on the primary purpose of the measurements and should be determined accordingly.
書誌情報 Radiation Protection Dosimetry

巻 185, 号 3, p. 402-408, 発行日 2019-12
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncz020
関連サイト
識別子タイプ URI
関連識別子 https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncz020/5365234
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:10:55.012040
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3