WEKO3
アイテム
Development of a neutron detector with a high position resolution at intermediate energies
https://repo.qst.go.jp/records/73418
https://repo.qst.go.jp/records/73418acd2aaa9-d898-4c05-9e8a-7b1e1c120300
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-02-18 | |||||
タイトル | ||||||
タイトル | Development of a neutron detector with a high position resolution at intermediate energies | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Y, Kubota,
× Y, Kubota,× Sasano, M× Uesaka, T× M, Dozono,× M, Itoh,× S, Kawase,× M, Kobayashi,× CS, Lee,× Matsubara, H× Miki, K× Miya, H× Ono, Y× S, Ota,× K, Sekiguchi,× T , Shima,× T, Taguchi,× TL, Tang,× Tokied, H× T, Wakasa,× Wakui, Takashi× J , Yasuda,× J, Zenihiro,× Wakui, Takashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A high position resolution neutron detector for time-of-flight measurements is being developed to measure the (p, pn) reaction in inverse kinematics with an excitation energy resolution of 1 MeV at the RIKEN RI Beam Factory. In this study, a new method based on the segmentation of the neutron detector part is employed to achieve a position resolution on the order of mm with a prototype neutron detector. The prototype detector consists of 8 x 8 scintillating fibers, two multi-anode photomultiplier tubes (PMTs) and two light guides. The scintillating fibers have a cross sectional area of 3.75x3.75 mm(2). The prototype's performance is studied using the neutron and proton beams provided at the Cyclotron and Radioisotope Center (CYRIC), Tohoku University and the Research Center for Nuclear Physics (RCNP), Osaka University. It is confirmed that the hit pattern analysis correctly recognizes the neutron detection position within the fiber size of 3.75 mm. The obtained TOF resolution of 350 ps (FWHM), lateral position resolution of 2.5 mm (FWHM), and longitudinal position resolution of 50-60 mm (FWHM) satisfy the requirements to achieve an excitation energy resolution of 1 MeV. The typical detection efficiency is similar to 2.0% for a neutron with a kinetic energy of 50-200 MeV. The detailed investigation of the detection efficiency in conjunction with the neutron hit position reveals the existence of the non-uniformity of the efficiency. It is shown that the non-uniformity can be mitigated by reducing the threshold level, and by increasing the detector size. For a larger neutron detector, based on the design of the prototype detector, the non-uniformity will thus be negligible. | |||||
書誌情報 |
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 巻 914, p. 32-41, 発行日 2018-10 |
|||||
出版者 | ||||||
出版者 | ELSEVIER SCIENCE BV, | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nima.2018.10.153 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0168900218314578 |