ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Radiation hardness of organic photodiode detectors for carbon beam irradiation

https://repo.qst.go.jp/records/73060
https://repo.qst.go.jp/records/73060
865e2858-524a-4352-8a66-e8eba489bd76
Item type 会議発表用資料 / Presentation(1)
公開日 2018-11-27
タイトル
タイトル Radiation hardness of organic photodiode detectors for carbon beam irradiation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 719992

Nishikido, Fumihiko

Search repository
Takada, Eiji

× Takada, Eiji

WEKO 719993

Takada, Eiji

Search repository
Shikida, Gen

× Shikida, Gen

WEKO 719994

Shikida, Gen

Search repository
Nitta, Munetaka

× Nitta, Munetaka

WEKO 719995

Nitta, Munetaka

Search repository
Takyu, Sodai

× Takyu, Sodai

WEKO 719996

Takyu, Sodai

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 719997

Yamaya, Taiga

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 719998

en 錦戸 文彦

Search repository
高田 英治

× 高田 英治

WEKO 719999

en 高田 英治

Search repository
鋪田 嚴

× 鋪田 嚴

WEKO 720000

en 鋪田 嚴

Search repository
新田 宗孝

× 新田 宗孝

WEKO 720001

en 新田 宗孝

Search repository
田久 創大

× 田久 創大

WEKO 720002

en 田久 創大

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 720003

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recently, many groups have been developing organic devices such as photodiodes, electroluminescence cells, photovoltaic cells, and transistors as various detection devices. These organic devices are thin, flexible, printable and inexpensive to manufacture. If they can be used in radiation measurements, it is expected that many innovative radiation detectors can be fabricated because of these desirable characteristics. Especially interesting are organic photodiodes (OPDs) that work like conventional Si semiconductor photodiodes. Based on these points, the OPDs are suitable for application as carbon therapy dosimeters. Therefore, we are investigating the OPDs as radiation detectors for heavy ion beam irradiation. In this presentation, we evaluate the radiation hardness of the OPD detectors to the carbon beam irradiation and report our results.
\nThe OPD detector structure consisted of layers of IZO/ PEDOT: PSS / PCBM: P3HT / Al. The OPDs were fabricated on 10 mm × 10 mm black ABS boards by spin coating; fabrication was done 3 days before an experiment. Various sizes of the OPD were used in the experiment. We performed the experiment in the PH2 course of the HIMAC at NIRS. The energy of the 12C beam was 290 MeV/u which is typically used in actual carbon therapy. The OPDs were irradiated by the 12C beam that passed through an ion chamber to monitor the number of irradiated particles. The beam intensity was 1.8×109 particles per second. The diameter of the 12C beam was 1 cm. The induced charges of the OPDs by the carbon beam irradiation and dark current components were measured in the experiment. Experimental results showed that the performance degradations of the OPDs by carbon beam irradiation were negligible for irradiation times in this experiment. Finally, we concluded that the radiation hardness of the OPD detector is sufficient for application as dosimeters for carbon beams.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 IEEE NSS-MIC2018
発表年月日
日付 2018-11-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:33:16.890507
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3