Analysis of radionuclidic purity of medical isotope production with d-Li neutron in A-FNS

https://repo.qst.go.jp/records/72959
https://repo.qst.go.jp/records/72959
24c24131-fbd0-4c4b-b276-040a7ff48ee5
Item type 会議発表用資料 / Presentation(1)
公開日 2018-09-26
タイトル
タイトル Analysis of radionuclidic purity of medical isotope production with d-Li neutron in A-FNS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 太田, 雅之

× 太田, 雅之

WEKO 718889

太田, 雅之

Search repository
権, セロム

× 権, セロム

WEKO 718890

権, セロム

Search repository
佐藤, 聡

× 佐藤, 聡

WEKO 718891

佐藤, 聡

Search repository
落合, 謙太郎

× 落合, 謙太郎

WEKO 718892

落合, 謙太郎

Search repository
鈴木, 寛光

× 鈴木, 寛光

WEKO 718893

鈴木, 寛光

Search repository
太田 雅之

× 太田 雅之

WEKO 718894

en 太田 雅之

Search repository
権 セロム

× 権 セロム

WEKO 718895

en 権 セロム

Search repository
佐藤 聡

× 佐藤 聡

WEKO 718896

en 佐藤 聡

Search repository
落合 謙太郎

× 落合 謙太郎

WEKO 718897

en 落合 謙太郎

Search repository
鈴木 寛光

× 鈴木 寛光

WEKO 718898

en 鈴木 寛光

Search repository
抄録
内容記述タイプ Abstract
内容記述 Using neutrons generated by d-Li reaction in the A-FNS, we analyzed radionuclidic purity of technetium-99m (99mTc). It is one of the most-used medical isotopes and the daughter radionuclide of molybdenum-99. The angular distribution of the neutrons by the d-Li reaction is isotropic, and the high energy neutrons around 14 MeV have strong angular dependence in the forward direction. The high energy neutrons produce various radioisotopes, because their energies are over threshold energies of nuclear reactions. We calculated neutron spectra in the A-FNS test cell by using the Monte Carlo transport code MCNP5 with the extension McDeLicious-11 and the nuclear data library FENDL-3.1d. Using the spectra, activation calculations were performed with the inventory calculation code FISPACT-2010. Ratios of the activity of 99mTc to that of other Tc radioisotopes were evaluated for the cooling time after the neutron irradiation. It was found that the purity met a medical demand after an adequate cooling time because of decrease due to the decay of radioisotopes. In addition, we clarified that the purity became higher after a chemical separation process of Tc.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 30th edition of the Symposium on Fusion Technology (SOFT 2018)
発表年月日
日付 2018-09-18
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:34:15.203895
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3