WEKO3
アイテム
A new hollow-dome phantom for normalization of the helmet-neck PET
https://repo.qst.go.jp/records/72852
https://repo.qst.go.jp/records/728521d0ac533-1c61-49ef-bf5d-dfd23a9041d0
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-06-18 | |||||
タイトル | ||||||
タイトル | A new hollow-dome phantom for normalization of the helmet-neck PET | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
田島, 英朗
× 田島, 英朗× 赤松, 剛× 岩男, 悠真× 脇坂, 秀克× 吉田, 英治× 山下, 大地× 山谷, 泰賀× Tashima, Hideaki× Akamatsu, Go× Iwao, Yuma× Wakizaka, Hidekatsu× Yoshida, Eiji× Yamashita, Taichi× Yamaya, Taiga |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: Dementia is a glowing social problem in the aging society. Toward early diagnosis of the dementia, we are developing a high sensitivity dedicated brain PET, helmet-neck PET, having a novel hemispherical detector geometry and an add-on detector at the back of the neck position. For PET systems, normalization is essential procedure to obtain accurate images. Rotating line sources or cylindrical phantom are typically used, but they cannot be placed inside the hemispherical gantry. Therefore, we have used a pool phantom fitting inside the detector geometry for the normalization of the helmet-neck PET. However, the attenuation medium of the pool phantom reduces the number of true event counts and increases scattered events, resulting in uncertainty of the normalization. In this study, we develop a hollow dome phantom as a more efficient normalization phantom without attenuation medium inside to reduce the attenuation and scattering. Material and Methods: The normalization phantoms were designed for the first helmet-neck prototype having 47 depth-of-interaction (DOI) detectors arranged in multiple rings with different diameters to form a hemispherical geometry with the inner diameter of 253 mm and 7 DOI detectors arranged as the add-on detector. We designed the hollow dome phantom with a combined shape of a hemisphere and a cylinder both with the inner diameter of 236 mm and the outer diameter of 248 mm having a cavity inside. The thicknesses of the walls and the cavity were 2 mm. The hollow phantom was fabricated by a photolithography technique. At first, we conducted Monte Carlo simulation using the Geant4 toolkit to compare the count rate of the true events and the scatter fraction of the pool phantom. Then we applied the developed hollow dome phantom to the helmet-neck prototype. Results: The true count rates of the pool phantom and the hollow dome phantom at the radioactivity of 5 MBq were 17 cps/kBq and 83 cps/kBq, respectively. The true count rate of the hollow dome phantom was 4.8 times higher than the pool phantom. The scatter fractions were 31% for the pool phantom and 5.3% for the hollow dome phantom. We observed significant reduction of the scatter events. Conclusions: The hollow dome phantom is effective for normalization data acquisition for the helmet-neck PET because of high true count rate and small amount of scatter events. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | SNMMI 2018 Annual Meeting | |||||
発表年月日 | ||||||
日付 | 2018-06-26 | |||||
日付タイプ | Issued |