Design of the JT-60SA cryogenic pipe system

https://repo.qst.go.jp/records/72835
https://repo.qst.go.jp/records/72835
848cc248-d6f1-446c-be8e-052051c8b91b
Item type 会議発表用資料 / Presentation(1)
公開日 2018-06-29
タイトル
タイトル Design of the JT-60SA cryogenic pipe system
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Natsume, Kyohei

× Natsume, Kyohei

WEKO 717522

Natsume, Kyohei

Search repository
Kamiya, Koji

× Kamiya, Koji

WEKO 717523

Kamiya, Koji

Search repository
Fukui, Kazuma

× Fukui, Kazuma

WEKO 717524

Fukui, Kazuma

Search repository
Kawano, Katsumi

× Kawano, Katsumi

WEKO 717525

Kawano, Katsumi

Search repository
Murakami, Haruyuki

× Murakami, Haruyuki

WEKO 717526

Murakami, Haruyuki

Search repository
Tsuchiya, Katsuhiko

× Tsuchiya, Katsuhiko

WEKO 717527

Tsuchiya, Katsuhiko

Search repository
Kizu, Kaname

× Kizu, Kaname

WEKO 717528

Kizu, Kaname

Search repository
Isono, Takaaki

× Isono, Takaaki

WEKO 717529

Isono, Takaaki

Search repository
夏目 恭平

× 夏目 恭平

WEKO 717530

en 夏目 恭平

Search repository
神谷 宏治

× 神谷 宏治

WEKO 717531

en 神谷 宏治

Search repository
福井 良磨

× 福井 良磨

WEKO 717532

en 福井 良磨

Search repository
河野 勝己

× 河野 勝己

WEKO 717533

en 河野 勝己

Search repository
村上 陽之

× 村上 陽之

WEKO 717534

en 村上 陽之

Search repository
土屋 勝彦

× 土屋 勝彦

WEKO 717535

en 土屋 勝彦

Search repository
木津 要

× 木津 要

WEKO 717536

en 木津 要

Search repository
礒野 高明

× 礒野 高明

WEKO 717537

en 礒野 高明

Search repository
抄録
内容記述タイプ Abstract
内容記述 JT-60SA is a tokamak device using superconducting coils to be built in Japan, as a joint international research and development project involving Japan and Europe. One design object of JT-60SA is maximization of the plasma volume and the instrumentation port availability in the condition that several buildings, heating instruments, and diagnostics of JT-60U are reused. The cryogenic pipe system of JT-60SA, which transfers cold helium from the helium refrigerator to cold components such as superconducting coils, thermal shield and divertor cryopumps, has two unique features due to the limited space mentioned above.
One of them is a complicated path. Relatively small 11 valve boxes and 5 coil terminal boxes are separately installed around the tokamak cryostat asymmetrically, instead of a simple large distribution box and a current feeder box.
The other is that several inlets to superconducting coils are placed on upper side of coils, which makes difficult requests for structural analyses because of the higher part of coils, the larger displacement due to the gravity load, the seismic load, vacuuming the cryostat, cooling down the cold components, and the electro-magnetic force by the plasma operation. For example, the cryogenic pipe interface of JT-60SA Toroidal Field Coil is displaced about 8 mm, 11mm and 38 mm toward radius, toroidal, and vertical direction.
In order to determine the design, structural analyses are conducted using ANSYS® software, which is a finite element analysis tool. The analysis result must satisfy that the stress for all pipes and their support structures are lower than the allowable stress of the material and there is no physical interference with any other components as a result of displacement. In this work, the strategy of analysis and the design for JT-60SA cryogenic pipe system are reported.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 30th Symposium on Fusion Technology (SOFT 2018)
発表年月日
日付 2018-09-20
日付タイプ Issued
戻る
0
views
See details
Views