ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

The project of another low-cost metaphase finder (second report)

https://repo.qst.go.jp/records/72830
https://repo.qst.go.jp/records/72830
462bf2be-f897-46ef-9c05-14c2342a3f94
Item type 会議発表用資料 / Presentation(1)
公開日 2018-06-20
タイトル
タイトル The project of another low-cost metaphase finder (second report)
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 古川, 章

× 古川, 章

WEKO 717485

古川, 章

Search repository
古川 章

× 古川 章

WEKO 717486

en 古川 章

Search repository
抄録
内容記述タイプ Abstract
内容記述 Biological dosimetry is used to estimate one's dose by biological phenomena. The most popular and “gold standard” phenomenon is the appearance of dicentric chromosomes in metaphase in white blood cells. The metaphase finder is a tool for biological dosimetry that finds metaphase cells on slide glasses. It consists of an automated microscope, auto-focus system, X-Y stage, camera, and computer. It does the image diagnosis of the microscopic images of the slide glasses, and displays the positions of metaphase cells. The metaphase finder was used for the personnel worked at Fukushima nuclear plant to know how much dose they irradiated. The author has already reported another new low-cost metaphase finder system at EPR Biodose 2013. The author and a software company were using new special software which was faster than conventional systems. We used a Nikon Eclipse Ni-E microscope with motorized X-Y stage, 4x objective lens and 1920 x 1024 pixels color camera for hardware. The software uses mathematical morphology filters, and the new function to compare the color of the image. The new system was compact and low-priced. And the remarkable point is, this system can applicable for not only human blood, but also non-human samples. Now, the system has been completed and the author determined its speed. It was 13 minutes and 56 seconds per slide, while capturing 1,333 images, which achieved the aim of the project. The next goals are to implement a new automated dicentric counter and then obtain a dose-response relationship for the new dicentric counter.
Conclusion: The metaphase finder system was completed and its speed determined. It was 13 minutes and 56 seconds per slide, while capturing 1,333 images. This accomplished the aim of the project.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 EPR Bopdpse 2018
発表年月日
日付 2018-06-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:35:35.557398
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3