Model evaluation of normal tissue response by mini-beam radiotherapy with ion beams

https://repo.qst.go.jp/records/72822
https://repo.qst.go.jp/records/72822
153ec33d-6014-43d3-80cc-a894a6cc8fe6
Item type 会議発表用資料 / Presentation(1)
公開日 2018-06-13
タイトル
タイトル Model evaluation of normal tissue response by mini-beam radiotherapy with ion beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 717422

Matsufuji, Naruhiro

Search repository
松藤 成弘

× 松藤 成弘

WEKO 717423

en 松藤 成弘

Search repository
抄録
内容記述タイプ Abstract
内容記述 Bragg peak characteristics of ion beams makes ion-beam radiotherapy advantageous over conventional X-ray. The localized dose delivery to the Bragg peak enables to control deep-seated tumor cells while sparing surrounding benign tissues. The Bragg peak gets shaper for heavier ions; additionally, the biological effectiveness of carbon and its vicinity also increases gradually in accordance with increasing energy loss. Idea of the mini-beam radiation therapy (MBRT) was initially studied with X-ray as a method to spare proximal normal tissues by irradiating through submillimeter slit collimator. Recent studies try to apply the MBRT concept for proton beam by interlacing multiple sparse heterogeneous fields. The combination of the MBRT with ion-beam RT may lead further reduction of normal tissue toxicities.
This study aims at assessing the efficacy of the MBRT with ion beams with commonly-used normal-tissue complication probability (NTCP) consideration.
A Monte Carlo code PHITS was used to simulate the spatial dose distribution of carbon 276 MeV/n and proton 145 MeV pencil beams in water. Incident energy was selected to reach 15 cm depth. The beam was aligned in parallel at interval of the full width at half maximum at the Bragg peak layer. Accordingly, Equivalent Uniform Dose (EUD) widely used in common NTCP models was assessed from dose deposited proximal to the Bragg peak layer by changing the organ-structure parameter. The result revealed that carbon-ion beam is advantageous over protons in reducing EUD to the proximal normal tissues, however, the advantage of the mini-beam delivery was found only in case the normal tissue has extremely parallel-like structure therefore sensitive to minimum dose within the volume. The result is compared with the other NTCP models.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 World Congress on Medical Physics and Biomedical Engineering 2018 (IUPESM2018)
発表年月日
日付 2018-06-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:35:41.377966
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3