ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Conceptual design of reference radiation field simulating secondary neutrons during carbon-ion radiotherapy

https://repo.qst.go.jp/records/72817
https://repo.qst.go.jp/records/72817
cd747de6-784c-4265-bbd2-3905dcf414ee
Item type 会議発表用資料 / Presentation(1)
公開日 2018-06-11
タイトル
タイトル Conceptual design of reference radiation field simulating secondary neutrons during carbon-ion radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 米内, 俊祐

× 米内, 俊祐

WEKO 717373

米内, 俊祐

Search repository
米内 俊祐

× 米内 俊祐

WEKO 717374

en 米内 俊祐

Search repository
抄録
内容記述タイプ Abstract
内容記述 The risk of radiation-induced secondary cancer is of great concern to long-term cancer survivors who received radiotherapy and people involved in radiotherapy, because normal tissues around the treatment target are potentially exposed to undesired doses.
Estimations of the risk for conventional radiotherapy with high-energy x-ray and electrons have been reported based on epidemiologic studies including dose estimations. On the other hand, for ion-beam radiotherapy (IBRT) such as proton and carbon-ion radiotherapies, the risk estimation derived from epidemiologic studies is difficult yet because it is more modern radiotherapy modality. In addition, since many radiation species such as secondary charged particles and neutrons are produced by primary beam through interactions with irradiation devices and patient body during IBRT compared to conventional radiotherapy, dose-response relationships depending on radiation quality has to be investigated. In particular, secondary neutrons are a high-LET radiation which leads to high relative biological effectiveness (RBE) and provide whole-body exposure, though the neutron dose in IBRT is low according to published dosimetric studies. So it is very important to clarify the dose-response relationship for neutron exposures following IBRT. However, the epidemiologic approach is not realistic yet as mentioned before, biological experiments with cells and animals have still a key role.
The goal of this study is a development of reference neutron field for simulating secondary neutrons during carbon ion radiotherapy (CIRT) with the broad beam method. As is well known, there is the dependence on neutron energy in RBE, so it is ideal to perform experiments in the real treatment room. But, such experiments should be limited considering constraints of time and biological hazard. It is, therefore, required for the reference field to simulate well the neutron energy spectrum in the treatment room. Here, conceptual design of the reference neutron field using Monte Carlo code, PHITS is shown.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 World Congress on Medical Physics and Biomedical Engineering
発表年月日
日付 2018-06-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:35:44.728538
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3