Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan

https://repo.qst.go.jp/records/72816
https://repo.qst.go.jp/records/72816
b8603146-494a-41d1-a431-34897a906688
Item type 会議発表用資料 / Presentation(1)
公開日 2018-06-11
タイトル
タイトル Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 717367

Kanematsu, Nobuyuki

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 717368

Matsufuji, Naruhiro

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 717369

Inaniwa, Taku

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 717370

en 兼松 伸幸

Search repository
松藤 成弘

× 松藤 成弘

WEKO 717371

en 松藤 成弘

Search repository
稲庭 拓

× 稲庭 拓

WEKO 717372

en 稲庭 拓

Search repository
抄録
内容記述タイプ Abstract
内容記述 Carbon-ion radiotherapy (CIRT) is generally evaluated with the dose weighted by relative biological effectiveness (RBE), while the radiation quality varying in the body of each patient is ignored for lack of such distribution. In this study, we attempted to develop a method to estimate linear energy transfer (LET) for a treatment planning system that only handled physical and RBE-weighted doses. The LET taken from a database of clinical broad beams was related to the RBE per energy with two polyline fitting functions for spread-out Bragg peak (SOBP) and for entrance depths, which would be selected by RBE threshold per energy per modulation. The LET estimation was consistent with the original calculation typically within a few keV/$\mu$m except for the overkill at the distal end of SOBP.
The CIRT treatments can thus be related to the knowledge obtained in radiobiology experiments that used LET to represent radiation quality.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 World Congress on Medical Physics & Biomedical Engineering
発表年月日
日付 2018-06-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:35:45.407455
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3