Optimum size of a calibration phantom for x-ray CT to convert Hounsfield units to stopping-power-ratios in charged-particle therapy treatment planning

https://repo.qst.go.jp/records/72805
https://repo.qst.go.jp/records/72805
3348c6ba-12db-4a4e-9c3c-d2e79d7be9b9
Item type 会議発表用資料 / Presentation(1)
公開日 2018-05-30
タイトル
タイトル Optimum size of a calibration phantom for x-ray CT to convert Hounsfield units to stopping-power-ratios in charged-particle therapy treatment planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 717293

Inaniwa, Taku

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 717294

Tashima, Hideaki

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 717295

Kanematsu, Nobuyuki

Search repository
稲庭 拓

× 稲庭 拓

WEKO 717296

en 稲庭 拓

Search repository
田島 英朗

× 田島 英朗

WEKO 717297

en 田島 英朗

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 717298

en 兼松 伸幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 In charged-particle therapy treatment planning, the volumetric distribution of stopping power ratios (SPRs) of body tissues relative to water is used for patient dose calculation. The distribution is conventionally obtained from computed tomography (CT) images of a patient.using predetermined conversion functions from the CT numbers to the SPRs. One of the biggest uncertainty sources of patient SPR estimation is insufficient correction of beam hardening arising from the mismatch between the size of the patient cross section and the calibration phantom for producing the conversion functions. The uncertainty would be minimized by selecting a suitable size of the cylindrical water calibration phantom referred to as an "effective size" of the patient cross section, L.effective.
In this study, we investigated the L.effective for pelvis, abdomen, thorax, and head and neck regions by simulating an ideal CT system using volumetric models of the reference male and female phantoms. The L.effective values were 23.3, 20.3, 22.7 and 18.8 cm for the pelvis, abdomen, thorax, and head and neck regions, respectively.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 57th Annual Conference of the Particle Therapy Co-operative Group (PTCOG57)
発表年月日
日付 2018-05-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:35:52.330496
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3