A software tool for analysis of linear energy transfer and biologically effective dose in carbon-ion radiotherapy

https://repo.qst.go.jp/records/72804
https://repo.qst.go.jp/records/72804
7d1fcc64-afd0-40fe-8152-fcaf999f266b
Item type 会議発表用資料 / Presentation(1)
公開日 2018-05-29
タイトル
タイトル A software tool for analysis of linear energy transfer and biologically effective dose in carbon-ion radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 717287

Kanematsu, Nobuyuki

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 717288

Matsufuji, Naruhiro

Search repository
Fukahori, Mai

× Fukahori, Mai

WEKO 717289

Fukahori, Mai

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 717290

en 兼松 伸幸

Search repository
松藤 成弘

× 松藤 成弘

WEKO 717291

en 松藤 成弘

Search repository
深堀 麻衣

× 深堀 麻衣

WEKO 717292

en 深堀 麻衣

Search repository
抄録
内容記述タイプ Abstract
内容記述 In treatment planning of carbon-ion radiotherapy (CIRT), the relevant dose includes the weighting of relative biological effectiveness (RBE) of the radiation, which is related to linear energy transfer (LET) varying strikingly in patient body. Since the RBE is evaluated for a reference biological endpoint, there could remain systematic LET dependence in clinical response, depending on disease type. In addition, hypofractionation being pursued in CIRT also affects the clinical response, which is generally estimated by biologically effective dose (BED). Applying recently proposed formalisms, we have developed an in-house software tool ReXiON using programming language Python with package PyDICOM to convert physical and RBE-weighted dose distributions to LET and BED distributions for a treatment plan. We applied the tool to realistic examples to demonstrate its potential for the investigation of the LET and fractionation effects, which would generally interest the CIRT community. Although the tool has been fully configured for our own use, it is basically a simple script and can be easily adjusted for others by themselves. It will potentially be useful for deeper understanding of clinical radiobiology.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 57th Annual Conference of the Particle Therapy Co-Operative Group and 5th Annual PTCOG-NA Meeting
発表年月日
日付 2018-05-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:35:52.980899
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3