ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

An individual calibration system for electrometer and ionization chamber of radiotherapy dosimeters

https://repo.qst.go.jp/records/72721
https://repo.qst.go.jp/records/72721
d68719a7-2c24-40a4-8acd-efbe1905cb30
Item type 会議発表用資料 / Presentation(1)
公開日 2018-03-22
タイトル
タイトル An individual calibration system for electrometer and ionization chamber of radiotherapy dosimeters
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takase, Nobuhiko

× Takase, Nobuhiko

WEKO 716262

Takase, Nobuhiko

Search repository
Sakata, Suoh

× Sakata, Suoh

WEKO 716263

Sakata, Suoh

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 716264

Endo, Masahiro

Search repository
Narita, Katsuhisa

× Narita, Katsuhisa

WEKO 716265

Narita, Katsuhisa

Search repository
Yamasita, Wataru

× Yamasita, Wataru

WEKO 716266

Yamasita, Wataru

Search repository
Hoteida, Masahiro

× Hoteida, Masahiro

WEKO 716267

Hoteida, Masahiro

Search repository
Sasaki, Yosuke

× Sasaki, Yosuke

WEKO 716268

Sasaki, Yosuke

Search repository
Usiroda, Tota

× Usiroda, Tota

WEKO 716269

Usiroda, Tota

Search repository
Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 716270

Mizuno, Hideyuki

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 716271

Fukumura, Akifumi

Search repository
佐方 周防

× 佐方 周防

WEKO 716272

en 佐方 周防

Search repository
水野 秀之

× 水野 秀之

WEKO 716273

en 水野 秀之

Search repository
福村 明史

× 福村 明史

WEKO 716274

en 福村 明史

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Since 2004, Association for Nuclear Technology in Medicine (ANTM) has been carrying out a calibration service for radiotherapy dosimeters, as the unique secondary standard dosimeter laboratory in Japanese external radiotherapy field. The service provides an absorbed dose to water calibration factor to a set of chamber and electrometer, at a single electrometer range.
Recently, the authors have established a charge calibration system for electrometer to provide calibration factor at each electrometer range. The new system allows chamber calibration without customer's own electrometers.
Method: We assembled a reference standard measurement device of charge with capacitors and a DC voltmeter. Those are traceable to the corresponding national measurement standard. A customer’s reference class chamber can be calibrated with the best relative expanded uncertainty of 1% (k=2) with the new system.
Result: We compared the results of electrometer with the calibration factors given in the ADCL’s certificate with A2LA accredited symbol. The calibration factors obtained be the authors and ADCL agreed within the relative expanded uncertainties. The results of ionization chambers also were compared with the calibration factors given in the NMIJ test report. Both factors agreed within relative expanded uncertainties.
Conclusion: New calibration system established by the authors has been verified by the two experiments. The individual calibration system for electrometer and chamber would simplify the quality control method of reference dosimeters at radiotherapy facilities.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 8th Japan-Korea Joint Meeting on Medical Physics (114th Scientific Meeting of JSMP)
発表年月日
日付 2017-09-16
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:36:48.103953
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3