ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Ultrahigh-Resolution Imaging of Bio-Samples with Modern and Future Ultrabright X-Ray Sources: the Source and Method Requirements

https://repo.qst.go.jp/records/72598
https://repo.qst.go.jp/records/72598
580354eb-f96c-461b-bf2b-be1fd795d7e1
Item type 会議発表用資料 / Presentation(1)
公開日 2017-12-20
タイトル
タイトル Ultrahigh-Resolution Imaging of Bio-Samples with Modern and Future Ultrabright X-Ray Sources: the Source and Method Requirements
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 ピロジコフ, アレキサンダー

× ピロジコフ, アレキサンダー

WEKO 715003

ピロジコフ, アレキサンダー

Search repository
ピロジコフ アレキサンダー

× ピロジコフ アレキサンダー

WEKO 715004

en ピロジコフ アレキサンダー

Search repository
抄録
内容記述タイプ Abstract
内容記述 Coherent x-rays promise breakthrough in imaging and especially time-resolved imaging, which is a critical technology for basic research, material- and bio-sciences. The key technique now is the Coherent Diffractive Imaging (CDI) and its variations. The achievable resolution is limited mainly by two factors: the available photon flux because large-angle diffraction efficiency is low, and the radiation damage which is especially severe for bio-samples. Thus, for bio-imaging with ultrahigh-resolution (i.e. better than several nanometers and ideally with atomic resolution), a powerful coherent x-ray source must provide a very large number of photons in a very short pulse so that single-shot exposure gives all necessary information before the sample is destroyed. Importantly, higher resolution requires shorter pulses as the acceptable displacement of the sample atoms gets smaller. This in turn requires larger x-ray pulse bandwidth, which at some point starts to contradict one of the main CDI requirements of very narrow bandwidth. I will analyze the performance of modern and future coherent x-ray sources (XFELs and laser-based compact sources including atomic harmonics and novel source based on x-ray emission from relativistic plasma singularities) and imaging methods and formulate requirements, in particular bandwidth requirements, that are necessary to achieve ultrahigh resolution. The work is supported by JSPS Kakenhi JP 26707031.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 1st QST International Symposium "Quantum Life Science"
発表年月日
日付 2017-07-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:38:02.331145
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3